Remote switching machines with a SMS text from your mobile phone!
Remote Monitoring your assets in the worldwide by your mobile Phone!
Remote Monitoring your assets in the worldwide by your mobile Phone!
The features and functions of RTU5000:
1. MOSFET Relay output, Current Drive ability note: >100mA, Patient Voltage note: 60V. It can be switched on by sending a SMS to the unit. Output mode: pulse. Outputs trigger by SMS commands, the width and the period of the pulse can also be set.(Optional,if you want to use it please buy the AQY22RS from Panasonic.);
2. 1 OC Drive Current: >500mA (continuous). Output mode: pulse. Outputs trigger by SMS commands, the width and the period of the pulse can also be set;
3. 1 AD channel: 0-5V, 8Bits, Input Impedance: 50KOhm. If AD input value is higher than the setting higher value, or If AD input value is less than the setting lower value, the unit will be activated;
4. 4 Opt coupler (Iso) Input, Input Drive Current: Min:0.5mA, Max:45mA (continuous) ,
Reverse Patient Voltage: 100V; Can setup as rising edge or failing edge or both the rising edge and the failing edge will activate the RTU;
2. 1 OC Drive Current: >500mA (continuous). Output mode: pulse. Outputs trigger by SMS commands, the width and the period of the pulse can also be set;
3. 1 AD channel: 0-5V, 8Bits, Input Impedance: 50KOhm. If AD input value is higher than the setting higher value, or If AD input value is less than the setting lower value, the unit will be activated;
4. 4 Opt coupler (Iso) Input, Input Drive Current: Min:0.5mA, Max:45mA (continuous) ,
Reverse Patient Voltage: 100V; Can setup as rising edge or failing edge or both the rising edge and the failing edge will activate the RTU;
5. 4 of the 4 Opt coupler (Iso) can be used as Counter Function, multiplexed counter channel, the falling edge and the rising edge of it will be invalid. The channel can be activated by a pre-setting value (time or quantity). If there is overflow, it will loop;
6. When System initialization complete (by power supply or battery), will send the SMS to SMS recipient 1;
7. When power supply on, while supported by back-up battery, will send the SMS to SMS recipient 1;
8 . If there is built in battery, RTU detects that the power level is lower than the pre-setting lower value, the event will be activated;
9. If the power supply disconnected or power off, the RTU will send SMS to SMS recipient 1;
7. When power supply on, while supported by back-up battery, will send the SMS to SMS recipient 1;
8 . If there is built in battery, RTU detects that the power level is lower than the pre-setting lower value, the event will be activated;
9. If the power supply disconnected or power off, the RTU will send SMS to SMS recipient 1;
10. Up to 4 mobile phones numbers can be pre-set as SMS Alarm number;
11. Up to 4 phones numbers can be pre-set as auto dialing Alarm number;
12 .Password protected, prevents unauthorized user;
13. Can be set up and programmed from any GSM phone or PC through RS232 Cable;
14. Time stamped alarm messages;
15. Based on GSM Network.
11. Up to 4 phones numbers can be pre-set as auto dialing Alarm number;
12 .Password protected, prevents unauthorized user;
13. Can be set up and programmed from any GSM phone or PC through RS232 Cable;
14. Time stamped alarm messages;
15. Based on GSM Network.