1. Features
◆ Color TFT screen, waveform  up to 8 channels
◆ Light and portable with build-in rechargeable battery
◆ UP to 10 kinds of monitor parameters
◆ Arrhythmia analysis, pace-marker detection and S-T segmentan alysis
◆ 72 hour storage and review of trend grams and tables, 40 second review of olographic wavefo rms
◆ All-round monitor of adult ,pediatric and neonatal
◆ Electrosurgical unit and defibrillation protected
◆ Standard parameters: ECG, NIBP, SpO2,  RESP,  TEMP, PR
 
2. Technical Specification
(1) ECG
◆ 5-lead or 3-lead selectable
◆ Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
◆ Lead selection: I; II; III; avR; avL; avF; Vx; CAL
◆ Gain selection: 12.5mm/s, 25mm/s, 50mm/s
◆ Accuracy: ±1bpm or ±1%, whichever is greater
◆ Protection: withstand 4000VAC/50Hz voltage in  isolation against elctrosurgical and defibrillation
◆ Calibration signal: 1mV±5%
◆ Operation modes: diagnostic, monitor, surgery
◆ Alarm range: adult: 15-300bpm
◆ Pediatric/Neonatal: 15-350bpm
◆ Alarm range: -2.0mV~2.0mV
◆ S-T detection: YES; arrhythmia analysis: YES
◆ Alarm: YES, audible and visual alarm, alarm events recallable
 (2) NIBP
◆ Method: oscillometry
◆ Operation modes: manual/automatic/STAT
◆ Measurement unit: mmHg/KPa selectable
◆ Measurement types: systolic, diastolic, mean
◆ Measurement range: adult, 10-270mmHg
◆ Over-pressure protection: YES
◆ Resolution: 1mmHg
◆ Accuracy: mean error and standard deviation   per ANSI/AAMI SP-10
◆ Alarm: systolic, diastolic, mean
 (3) SpO2
◆ Measurement range: 0-100%
◆ Accuracy: ±2digit (70~100%)
◆ 0~69% unspecified
◆ Alarm range: 0-100%
 (4) Respiration
◆ Method: RA-LL impedance
◆ Pediatric/neonatal: 6-150rpm
◆ Alarm range: adult: 6-120rpm
◆ Pediatric/neonatal: 6-150rpm
◆ Apnea alarm: YES
 (5) Temperature
◆ Resolution: 0.1℃
◆ Channel: dual-channel
◆ Alarm range: 0-50℃
 (6) EtCO2
◆ Measurement mode: side-stream or mainstream
◆ Measurement range: EtCO2: 0-99mmHg
◆ Accuracy: CO2 concentration
◆ Apnea alarm: YES
 (7) CO
◆ Method: Thermo-dilution
◆ Measurement range: CO, 0.1-20 lit./min.
 (8) IBP
◆ Channel: 2 channels
◆ Pressure transducer: Sensitivity: 5( mV/V/mmHg)
◆ Transducer sites: ART, PA, CVP, RAP, LAP, ICP
◆ Alarm range: -10~300mmHg
 
3. Standard  Configuration
◆ Main unit                                      1 set
◆ Body temperature probe           1 set
◆ SpO2 probe                                 1 set
◆ NIBP cuff                                      1 set
◆ ECG lead cable                          1 set
◆ Disposable electrode                10 pcs
◆ Grounding wire                           1 set
◆ Power supply cable                   1 set
◆ User manual                               1 copy
 
4. Optional
◆ EtCO2, CO, IBP
◆ Thermal  printer