model Specifications and parameters | C1K | ||||||
Rated power | 1000VA/800W | ||||||
AC Input | Input system | Single phrase & earth ground | |||||
Ranged voltage | 208/220/230/240Vac | ||||||
Frequency | 50/60Hz | ||||||
Voltage range | 115~300VAC±5 | ||||||
Frequency range | 50/60±5Hz | ||||||
Voltage range of bypass | 80VAC×(1±5%)285VAC×(1±5%) | ||||||
Battery | Voltage range of battery | 36VDC | |||||
Input | |||||||
Battery capacity*Quantity | 12VDC*3 | ||||||
Backup Time (half/full loaded) | Half loaded≥10minutes, Full loaded ≥5minutes(standard) | ||||||
Transient rush current in boot-up state | <150% of rated current | ||||||
Battery charger time | Charger to 90% battery capacity in 5 hours(standard) | ||||||
Dependent on the capacity of external batteries(long backup time) | |||||||
AC | Output system | Single phrase&earth ground | |||||
Output | |||||||
Output voltage | 220/110Vac±3%(inverter output) | ||||||
Output frequency | 50/60±5Hz(normal) 50/60Hz±1%(abnormal) | ||||||
Dynamic voltage transient range | <5% | ||||||
Dynamic transient restore | < 60ms | ||||||
Waveform | Sine WaveTHD<3%(linear load) Sine WaveTHD<8%(nonlinear load) | ||||||
Input powerfactor | 0.8 | ||||||
Overload capability | 105125%≥ 60s, 126150%≥30s The recover point is 90% | ||||||
Input current peak coefficient | 31 | ||||||
Transfer time | < 0ms | ||||||
Panel indicator system | LED indicator, show the status | ||||||
of UPS and operation parameter | |||||||
Communications | RS232(turn to 485), stem node | ||||||
Alarm Function | AC/DC input under abnormal , overload condition | ||||||
and inverter problems | |||||||
Protection Function | AC input or output above or below the range of voltage | ||||||
Overload , over | |||||||
temperature and short circuit protection | |||||||
Conduction | Satisfy YD/T983-1998A | ||||||
Radiation | Satisfy YD/T983-1998A | ||||||
Noise Immunity | Satisfy YD/T983-1998A | ||||||
Insulating resistance | > 2MΩ500VDC | ||||||
Insulating strength | 2121VDC(AC input, output to ground, DC input to AC output), | ||||||
without flashover in one minute) | |||||||
Cooling system | wind cooling | ||||||
Frequency | <55dB(1M) | ||||||
Working | Temperature | 10~ +40 | |||||
enviroment | |||||||
humidity | 0~95%, no condensation | ||||||
Altitude | ≤1500m, satisfy GB3859.2-93 | ||||||
Storage | Inverter temperature | -40~+65 | |||||
envirement | |||||||
humidity | 0~95%, no condensation | ||||||
Dimensions(mm)(W*H*D) | 145 X 355 X 236 |
UPS application online specification:
1. Digital Design
2. Reversed Polarity N and L wire Detection Function.
3. A Real Green-environmental Protection Power.
4. Direct Current Cold Start Function
5. Alarm High-low Battery Input Voltage Protection Function
6. Communication and Monitoring Function
7. Output High- Low Voltage Protection
8. Output Short Circuit Protection
9. Overloaded Protection Function
10. Over-temperature Protection
11. Intelligent Fan Speed Control Function
According to load capability and environmental temperature
Applications:
Work stations & Networks
Automatic Control Systems
Automatic and Medical equipment
Laboratory and Medical equipment
Security and Emergency Systems
Banking and Data Processing
Computer and Communications