Description of autodial alarm system:
4 zones Burglar Alarm System
Protection different zone: 4 zones indicated on panel.
. Each zone can be put more sensors.
. Partial disarmed optional by remote control. One keypad easy to partial disarmed some sensors.
. Auto-dial up 13 phone numbers and recycle to repeat unless confirmed.
. Store voice recorded message (10 second), it can be recovered. When received alarm message, it speaks as you spoken.
. NI-MH rechargeable battery to back up power: > 24 hours.Auto-switch if AC power is off.
. Telephone manages the alarm system, convenience.
. Phone trunks protected to avoid any designing destroy.
. LED on the panel to display protection zone.
. PIR detector is preset for the second zone which can be disarmed solely
. Audible/mute siren optional.
. Quick program by the panel keyboard.
. When received alarm call, you can press the keypad on the phone to disarm/arm/monitoring/start on/off siren
. Incoming calling password protected
. Alarm time can be customized.
. All panels can connect with the alarm receipt managing center
. Each zone can be put more sensors.
. Partial disarmed optional by remote control. One keypad easy to partial disarmed some sensors.
. Auto-dial up 13 phone numbers and recycle to repeat unless confirmed.
. Store voice recorded message (10 second), it can be recovered. When received alarm message, it speaks as you spoken.
. NI-MH rechargeable battery to back up power: > 24 hours.Auto-switch if AC power is off.
. Telephone manages the alarm system, convenience.
. Phone trunks protected to avoid any designing destroy.
. LED on the panel to display protection zone.
. PIR detector is preset for the second zone which can be disarmed solely
. Audible/mute siren optional.
. Quick program by the panel keyboard.
. When received alarm call, you can press the keypad on the phone to disarm/arm/monitoring/start on/off siren
. Incoming calling password protected
. Alarm time can be customized.
. All panels can connect with the alarm receipt managing center
Technical Parameter:
Standby Current:≤20mA, Alarming Current:≤50mA,
Working Conditions:indoors; teperature:-10 to 50
relative humidity≤90%; atmospheric pressure 86 ~106Kpa.
Alarm receiving method:wireless transmission; radio transmitted distance:≥100m;
Voice message:12 seconds
Phone number savable:15 groups, 30 digit
Horn level of the siren connected:≥110dB.
DTMF:circular current 80mA 35mA 18mA
Standard Package list of the Autodial Alarm System
Mainframe X1
Remote contol X2
Wireless PIR Motion Sensor X1
Wireless Door magnetic Sensor X1
AC/DC AdaptorX1
User Manual X1