Product Main

Specifications

Features of Triple-layer co-extrusion dry-cure CCV lines(6-35KV, 35KV-123KV)
1.Controlled by computer and operated by touch srceen, communicates with profibus.
2.Adopt ¢65 conductor shield, ¢150 insulation, ¢90 insulation shield, triple-layer co-extrusion.
3.Controlled by field density,shifting phase trigger function of tubes.
4.The specially designed triplelayer coextrusion crosshead ensure the joint speed raising not to eccentric after modulating with low speed and can made finished cable after 30-40m.
5.The manmachine communicate menu can deposite the technological parameter to use at any moment.
6. Sag control. The working principle is of contactless type with the features of narrow band emission, strong signal, weak signal receiving and high anti-interference ability, used widely DC speed governing and AC frequency conversion control.
 
Technical parameters of  of Triple-layer co-extrusion dry-cure CCV lines (6-35KV, 35KV-123KV)
Voltage class
XLPE: 6-35KV
XLPE: 35-132KV
Conductor sections
Copper: 35-630mm2
Copper: 50-1600mm2
 
Aluminum: 50-800mm2
Aluminum: 70-1600mm2
Max. cable weight
10kg/m
16kg/m
Max. diameter
Ф75mm
Ф95mm
Tube layout
Half-catenary
Half-catenary
Nitrogen
Pressure: 2.0-2.5Mpa
Purity: 99.5%
Pressure: 2.0-2.5Mpa
Purity: 99.5%
Consumption
Standard atmoshpencpressure
Volume of nitrogen tank: 5m3
Standard atmoshpencpressure
Volume of nitrogen tank: 5m3
Cooling water
Pressure: 0.2-0.6Mpa
Circulation: 25m3/h
Pressure: 0.2-0.6Mpa
Circulation: 25m3/h
Compressed air
Pressure: 0.6-0.8Mpa
Normal dosage: 0.8m3/h
Pressure: 0.6-0.8Mpa
Normal dosage: 0.8m3/h
Installed capacity
750KVA-930KVA
900KVA-1080KVA
Total weight
80t-90t
100t