SM Simplex/Duplex SC-SC Fiber-optic Patch Cords Suitable for Telecommunications
Fiber optic patch cables are suited for equipment jumper cord, cross connects, and work area connections. All patch cables are manufactured using riser grade cable and are factory tested to make sure performance to meet Telcordia standards. Patch cords are available in both multimode and singlemode in duplex and simplex.
Fiber optic patch cables are suited for equipment jumper cord, cross connects, and work area connections. All patch cables are manufactured using riser grade cable and are factory tested to make sure performance to meet Telcordia standards. Patch cords are available in both multimode and singlemode in duplex and simplex.
Applications:
1. High bit rate data transmission
2. Fiber optic communication networks
3. Testing instruments
4. Active device terminations
5. CATV, LAN, MAN, WAN, Test &Measurement
6. FTTX.
1. High bit rate data transmission
2. Fiber optic communication networks
3. Testing instruments
4. Active device terminations
5. CATV, LAN, MAN, WAN, Test &Measurement
6. FTTX.
Features:
1.- SM & MM available
2.- Standard & custom configurations
3.- Meets Telecordia-GR-326-CORE specifications
4.- Low insertion loss
5.- Polishing: PC/UPC,APC
6.- For 3.0mm,2.0mm jacket or 900μm buffer.
1.- SM & MM available
2.- Standard & custom configurations
3.- Meets Telecordia-GR-326-CORE specifications
4.- Low insertion loss
5.- Polishing: PC/UPC,APC
6.- For 3.0mm,2.0mm jacket or 900μm buffer.
Spec:
- Insertion loss:
SM: ≤0.2dB
MM: ≤0.5dB
- Return loss:
PC polish: ≥35dB
UPC polish: ≥50dB
APC polish: ≥65dB
- Each test insertion loss changes:
- Interchangeable test: ≤0.2 dB
- The vibration test: ≤0.1 dB (10-60Hz, 1.5 mm amplitude)
- Tensile tests: ≤ 0.1 dB (0-15Hg tension, φ 0.9 mm fiber except)
- High temperature testing: ≤0.2 dB (+ 85 ° c for 100 hours),
- Low temperature test: ≤0.2--40 degrees Celsius (dB for 100 hours),
- The temperature cycling tests: ≤ 0.2 dB (- 40 ~ 85 ° c + 5 times),
- Humidity test:≤ 0.2 dB (+25 ° ~ + 65 ° c, relative humidity 93%, 100 hours),
- Insertion loss:
SM: ≤0.2dB
MM: ≤0.5dB
- Return loss:
PC polish: ≥35dB
UPC polish: ≥50dB
APC polish: ≥65dB
- Each test insertion loss changes:
- Interchangeable test: ≤0.2 dB
- The vibration test: ≤0.1 dB (10-60Hz, 1.5 mm amplitude)
- Tensile tests: ≤ 0.1 dB (0-15Hg tension, φ 0.9 mm fiber except)
- High temperature testing: ≤0.2 dB (+ 85 ° c for 100 hours),
- Low temperature test: ≤0.2--40 degrees Celsius (dB for 100 hours),
- The temperature cycling tests: ≤ 0.2 dB (- 40 ~ 85 ° c + 5 times),
- Humidity test:≤ 0.2 dB (+25 ° ~ + 65 ° c, relative humidity 93%, 100 hours),