FEATURE:
Micro-controller digital accuracy
Micro-controller digital accuracy
PWM charge mode
State of charge (SOC)
Temperature compensation
Automatic detection of voltage
External temperature sensor
Single digital LED display, number equal to time setting
Five working modes: Light control; light control on + time control off,
test mode; manual mode,
light control on + time control off - time control on + light control off
Technical Parameters:
HC12-10(D)-T series: 12 VOLT or 12/24VOLT auto work 10A/15A/20A(for PV and load)
Rated current: 10Amps; 15Amps; 20Amps
Self-consumption: ≤2.8mA
Over charging protection: 17Volt
Working temperature: -35℃ to +55℃
Boost voltage: 14.6Volt
Float voltage: 13.6Volt
Charging return voltage: 13.2Volt
Temperature compensation: -4.5mv/℃/2Volt
Low voltage: 12.0Volt
Over discharging return voltage: 12.6Volt
Over discharging voltage: 11.1Volt
NOTES: It is foe 12V system, please ×2 for 24V system
ELECTRONIC PROTECTION
Over charge or over discharge protection
Over load protection
Short circuit protection
Reverse polarities protection
Reverse current protection at night
LIGHTING CONTROL OPTION
• Press the power switch for 5 seconds, and select the desired LIGHTING CONTROL option. The LED is on, which confirmed you have selected the right one.
• The controller requires 10 minutes of continuous transition values before it starts to work. These constraints avoid false transitions due to lightning or dark storm clouds.
0,1,2,3,4,5,6,7
|
Hours light is turned on after sundown
|
0.
|
12 hours light is turned on after sundown
|
1.
|
Dusk-to-Dawn, light is on all light
|
2.
|
Lights remain turned off, ON/OFF mode
|
3.
|
Test mode, lights on after it detects no light, lights off after it detects light.
|
4. or 5. or 6. or 7.
|
Light is turned on for 2 hours(or 3 hrs, or 4 hrs, or 5 hrs)after sundown, turned off then, and turned on for 2 hours(or 3hrs, or 4hrs,or 5 hrs) before sunrise.
|
• 10 minutes off before the controller start to work.
A brief description follows below: