HONGDU TESTING EQUIPMENT CO.,LTD.
HD-28 Power Plug Integrated Tester
Product explanation:
This tester is a integrated tester for plug.It is used to test the continuity, insulation, high-volt, leakage current of power plug.It meets the requirements of many international standards such as BIS, UL, CSA, VDE, BSI, DIN, CCC, IEC,etc.The biggest advantage of this machine is it can test 28 plugs at the same time,it will rapidly promote your testing speed. It is a totally automatic testing machine make your operation more convenient and simple.
Features:
* All of the test subjects will done automatically.
* The inner/outer high-volt output value and persistence period can be set separately.
* Test speed is quick,all test subjects will be achieved in 2 seconds.
* The PLC control system comes from Mitsubishi,Made In Japan.
* The relay comes from Schneider,Made In French.
* If the specimen is incompetent,there is a alarm by buzzer and light.
* If the specimen is incompetent,this machine will stop at once and show you which subject is incompetent.Until you push the emergency button it will restart to a new test.And a switch with key can be made to order to replace the high-volt starting button,it is very useful,because when a alarm happen,the operaters can not restart this machine,only after the managers have checked over and restart it by key the machine will work again.
* When test over,the sample will be pushed out automatically,and a “T” or other characters will be marked on it(English characters only).
* 28 plugs can be inserted into the end to perform test,when test over,they will be pushed out together.
Technical parameter:
Items
|
Explanation
|
||
High voltage test
|
Output voltage
|
Outside high voltage
|
(L, N, E and cover) 0-5KV (adjustable)
leakage current:1,2,3,5,10mA (adjustable)
|
Interelectrode high voltage
|
0- 5KV (adjustable)
|
||
Rated power
|
500VA
|
||
Profile
|
50/60Hz
Exchange sine wave
|
||
Voltage calibration
|
within +-5%
|
||
Switch
|
Zero Level Translators
|
||
Voltage digital meter
|
Proportion
|
1: 50
|
|
Rank
|
1.0 CLASS
|
||
Fault Judgment
|
Judgement
|
The observed value is bigger than the datum value,Shuts off the output voltage and alarm.
|
|
Enact leakage current value
(benchmark value) |
0.5/1/2/3/5/10 mA
|
||
Judgement precision
|
+-5%
|
||
Inspects the no-load output voltage
|
About 200V 2.5mA stalls, short L, N ,and it must alarm.
|
||
Dielectric resistance
|
Output voltage
|
500VDC
|
|
Voltage calibration
|
+-5%
|
||
benchmark value
|
5/100MΩ
|
||
Judgment
|
The measured object insulation resistance value is smaller than the benchmark value, given the failure signal.
|
||
Judgment precision
|
+-5%
|
||
Single polarity and continuous testing
|
Polarity test
|
You have to test each wires in sequence.
|
|
CON test
|
You don’t have to test each wires in sequence.
|
NOTICE:
1,Inner high-volt is applied between L,N,E wires,and the outer high-volt is applied between L,N,E wires and jacket.
2,Both 3-wire and 2-wire power plug can be tested by this machine.
Test Objects:
Power Plugs