cummins 200 kw diesel generator,cummins 250 kva generator for sale
|
200KW/250KVA Cummins Diesel generator Technical Specifications
|
|||||
|
OPEN-TYPE
|
|||||
|
200 kw diesel generator set(250 kva diesel generator) are drove by Cummins Brand diesel engines manufactured by DCEC,and are connected with brushless generator fo Marathon or Stamford series and switch-broad,according to the requirements of our clients.The gensets have special devices for water temperature,oil temperature,low oil pressure and over-speed protection,so the products have many characteristics such as high precise voltage adjustment,excellent dynamic performance,stable voltage,long time efficient and economicetc
|
|||||
|
Model
|
200KW/250KVA
|
||||
|
GENERATOR SET
|
Rated Frequency (Hz)
|
50
|
|||
|
Rated Output Power (KW)
|
200
|
||||
|
Rated Voltage (AC) (V)
|
230/400
|
||||
|
Rated Current (AC) (A)
|
360
|
||||
|
Power Factor (COSΦ)
|
0.8 (lag)
|
||||
|
Power Supply
|
AC, 3-phase, 4-lines
|
||||
|
Diesel generator set size
|
2390×980×1530
|
||||
|
Diesel generator Weight(kg)
|
1750
|
||||
|
ENGINE
|
Engine Brand
|
Cummins
|
|||
|
Engine Model
|
6LTAA8.9-G2
|
||||
|
Number Of Cylinders
|
6
|
||||
|
Engine build
|
Line
|
||||
|
Fuel type
|
#0 Diesel (Natural temperature)
|
||||
|
Fuel Consumption (g/KW/h)
|
≤206
|
||||
|
Piston diameter and stroke
|
114*135
|
||||
|
Rated Rotation Speed (r/min)
|
1500
|
||||
|
Starting Method
|
24V Electric starting
|
||||
|
Cooling Method
|
Closed cycle water-cooled
|
||||
|
Speed Regulation
|
E
|
||||
|
ALTERNATOR
|
Alternator Brand
|
Marathon
|
|||
|
Alternator Model
|
MP-200-4
|
||||
|
Rated Output Power (KW)
|
200
|
||||
|
Phase & Threads
|
three phase four threads
|
||||
|
Insulation Class
|
self excitation
|
||||
|
Brushless
|
|||||
|
H
|
|||||
|
Voltage Regulation
|
AVR
|
||||
|
Protection class
|
IP23
|
||||
|
Main Electric Performance
|
|||||
|
Diesel Generators Voltage
|
|||||
|
Stable State Rate
|
Instantaneous State Rate
|
Stable Time
|
Fluctuation Rate
|
||
|
1%
|
-15%~+20%
|
1S
|
0.5%
|
||
|
Diesel Generator Frequency
|
|||||
|
Stable State Rate
|
Instantaneous State Rate
|
Stable Time
|
Fluctuation Rate
|
||
|
3~4%
|
8~12%
|
5~10S
|
0.5%
|
||