l With micro-CPU control, DC/AC inverter is an intelligent model product with good designing and reliability.
l Adopting SPWM technology, with the output of stabilized voltage and frequency, pure sine-wave.
l The inverter has good compatibility, built-in by-pass switch, high overload feature for reliable and continuous power supply.
l AC power type and DC power type:
l --AC power type means the city power supply is main when the city power is normal, when city power is off, inverter comes into work state.
l --DC power type means the inverter power supply is main when the city power is normal, when inverter power is off, city power comes into work state automatically.
l With the excellent designing, DC/AC inverter can be auto switched to bypass on the running state, its easy to maintain and replace the battery without effecting load power supply.
l In case there is battery voltage high/low or overload, the overload warning shutdown output, when battery voltage recovers normal, battery voltage recovers; power supply output will auto recovers in 50 seconds after overload off. This function is very suitable for the communication station in which there is no person on duty.
l Support network communication system, and power working state can be monitored by the supervision software.
l DC/AC inverter provides with two dry connectors which can be used for DC input fault checking and AC output problem warning.
Technical parameter
Technical parameter
Output power | 1KVA | |||||
Run mode | Pure inverter/online interactive | |||||
DC Input | Rated input voltage | 24V | ||||
Rated input current | 50/25 | |||||
Turn-off voltage range | 20V-30V / 40V-60V | |||||
Turn-on voltage range | 22V-28V / 45.5V-57V | |||||
Anti-noise current irrigation | ≤10% | |||||
AC Input | Bypass voltage | 220±10% | ||||
Rated input current(A) | 4.5 | |||||
Bypass transfer time(ms) | ≤5ms | |||||
AC Output | Power factor | 0.7 and 0.8 | ||||
Rated capacity | 1000VA | |||||
Rated output power | 800W | |||||
Rated output voltage and frequency | 220Vac, 50Hz | |||||
Wave shape | Pure sine wave | |||||
Rated output current | 3.6A | |||||
Output voltage accuracy | 220 V±2% | |||||
Output frequency accuracy | 50Hz±0.1% | |||||
Waveform distortion | ≤3% | |||||
Dynamic Response Time | 0.05 | |||||
Overload | 120%, 30s | |||||
Inverter efficiency(80% Resistive load) | ≥85% | |||||
Work environment | Dielectric Strength | Input & output 1500Vac, 1min | ||||
Noise(1m) | ≤40dB | |||||
Ambient temperature | -25℃~+50℃ | |||||
Humidity | 0~95%, Non-condensing | |||||
Altitude(m) | ≤1500 | |||||
Cooling | Forced air | |||||
Interface communication interface | HMI | LCD+LED display | ||||
Communication interface | RS232 or RS485 or RJ45(choose one) | |||||
dry contact load output | 2ch /3 ch output ( Choose one) | |||||
TCP/IP network interface | Optional | |||||
Protection | Input undervoltage, overvoltage; output overload, short circuit protection; AC input high and low voltage protection | |||||
Output wiring | Sockets and terminals |