Product Main

Specifications

Features and Specifications:

Unit Size
160mm *106mm
Unit Packing Way
Brown box
Unit Packing Size
21x13.8x5.5cm
Accessories

User Manual, warranty card

Function Introduction
Conventional Function

offline operation; real time supervision; photo display; mass storage; flexible user privilege setup; remote unlocking; multi-user supervision; quick setting; convenient checking and query; revisable and printable report form; report form;report can be exported to excel file; card+password unlocking; alarm for long time unclosing;alarm for invalid card swiping; first card unlocking;alarm for illegal break in; unlocking at definite time; e-map etc.

Professional function

for professional users such as bank,cash house, telecom station, power supply station,prison and plice station: interface locking; intimidation alarm; integrated fire control;anti-passback and anti-tail; interlocking;multi-card unlocking; emergency double locking; in door population checking; unlocking based on internal and external validation.

all-in-one-card management system

nomal shift and multi-shifts time attendance management system; fixed ration dining management system; meeting attendance management system; online patrol management system and security alarm management system.

Parameter
Communication

RS232 RS485 no need jumper and adaptive 9600 bps

English Software supportable database:

Access and SQL
Description

Control 1 door, get in and out door by swiping card, or get in by swiping card and get out door by button

Power Supply
12VDC 4-7A

Power Consumption of Circuit Board

Less than 100mA
Input Format of Reader

Wiegand 26 (All card reader with compatible protocol, such as Motorola , HID, EM , Mifare one etc)

Quantity of Readers
2pcs
Door Controlled
1

Door opening time extending setting

1-600 seconds(adjustable)

Max q ' ty of controller

N*256PCS
 

Remark: N denotes q ' ty of computer serial prot or q ' ty of 485hub port, support 256pcs ports

Operation Temperature
minus 40℃-70℃
Operation Humidity

10-90 % RH , No Condensation

Q ' ty of users
20,000 Users

Q ' ty of Event Buffers(offline)

100,000 event buffers

Power interruption protection measure

High Speed Memory, Records never lose

Max Distance from Reader to Controller

100m (suggestion distance 80m)

Max Distance between Controllers

RS232: Communication Distance less than 13m, suggestion distance is 3m or less

RS485: bus line max length 1200m, suggestion length 1000m or less, if expansion device added, the distance could be 3000m

TCP/IP: Depends on net coverage area

Collocations

PCB board, case, power, power line, serial port communication line, software, manual, certificate, key(2pcs), carton

Alarm for long time door open, ilegal break in, intimidate

Yes
Fire and alarm linkage

If no connection with the expansion board, only has software interface alarm, and drive the computer speaker. If connected with expansion board, is able to alarm by hardware, if connected with strengthened expansion board, then is able to Security alarm