EIRI-M1 is specially designed for remote monitoring and detecting of elevated body temperature in crowded situations. It combines advanced technology in infrared sensing, optoelectronics, computerized data/graphic processing and infor5mation technology to deliver a high performance infrared system for mass thermography.
Employing the latest un-cooled FPA detector, EIRI-M1 offers exceptional temperature resolution, outstanding spatial resolution, powerful image processing and long term continuous operation capabilities. It can rapidly and unobtrusively screen out suspicious febrile individuals without hindrance to the flow of traffic of the targeted crowd.
Features
Non-contact and non-invasive temperature measurement
Rapid temperature measuring time: No more than 0.1second
Precise temperature measurement: ± 0.2Celsius within measuring distance range 3~5M
Automatic calibration system to adjust for changes in ambient temperature for continuous accuracy
EIRV1m is designed especially for body temperature measurement with extreme precision in the range of +20Celsius to +50Celsius
Able to monitor large volume, fast moving crowds
Automatically tracking and reporting highest temperature in targeted population
Automatic audio and visual warming system to alert operators when targets within a pre-set temperature range are detected
Automatic exclusions of targets that exhibit abnormal high temperature
Supplemented with a visible spectrum CCD camera for accurate target identification
Applications
EIRI-M1 is widely applied to body temperature monitoring in congestive areas with large general population volume under high throughput, such as train stations, bus stations, ferries, airport, hospitals, department stores, government buildings, business buildings, and other related places. It is an ideal & professional fever screen infrared thermal camera system.
Main Technical Paramters Item Tehcnical Specifications Remark
Detector uncooled FPA micro-bolometer
Array size 320 x 240 pixel
Spectral range 8~14µ M
Field of view 22.4° X 16.8° 40mm F0.68
Frame rate 50Hz
Thermal sensitivity 0.08Celsius
Spatial resolution 1.2mrad
Measurement accuracy ± 0.2Celsius
Temperature measuring range +25Celsius ~ +42Celsius
Focus range 0.5m~∞
Operating temperature +16Celsius to +32Celsius Relative humidity no more than 85%
Storage temperature -20Celsius to +50Celsius Relative humidity no more than 95%
Power supply AC110~220V 50~60Hz
Measurement distance 3~5m
Digital output 14bit
Interface USB 2.0 connect to PC
Image display 256 color CSTN
Application software application software is stored in CD. Double click install. Exe in CD, and setup program will run automatically. Application software is running under Windows 2000/XP/98
Drive software USB interface driver (specified)
Computer configuration P4 CPU / 256M RAM / Hard disk / 17" CRT Monitor / CD-ROM / Keyboard / Mouse Motherboard must support USB 2.0
Employing the latest un-cooled FPA detector, EIRI-M1 offers exceptional temperature resolution, outstanding spatial resolution, powerful image processing and long term continuous operation capabilities. It can rapidly and unobtrusively screen out suspicious febrile individuals without hindrance to the flow of traffic of the targeted crowd.
Features
Non-contact and non-invasive temperature measurement
Rapid temperature measuring time: No more than 0.1second
Precise temperature measurement: ± 0.2Celsius within measuring distance range 3~5M
Automatic calibration system to adjust for changes in ambient temperature for continuous accuracy
EIRV1m is designed especially for body temperature measurement with extreme precision in the range of +20Celsius to +50Celsius
Able to monitor large volume, fast moving crowds
Automatically tracking and reporting highest temperature in targeted population
Automatic audio and visual warming system to alert operators when targets within a pre-set temperature range are detected
Automatic exclusions of targets that exhibit abnormal high temperature
Supplemented with a visible spectrum CCD camera for accurate target identification
Applications
EIRI-M1 is widely applied to body temperature monitoring in congestive areas with large general population volume under high throughput, such as train stations, bus stations, ferries, airport, hospitals, department stores, government buildings, business buildings, and other related places. It is an ideal & professional fever screen infrared thermal camera system.
Main Technical Paramters Item Tehcnical Specifications Remark
Detector uncooled FPA micro-bolometer
Array size 320 x 240 pixel
Spectral range 8~14µ M
Field of view 22.4° X 16.8° 40mm F0.68
Frame rate 50Hz
Thermal sensitivity 0.08Celsius
Spatial resolution 1.2mrad
Measurement accuracy ± 0.2Celsius
Temperature measuring range +25Celsius ~ +42Celsius
Focus range 0.5m~∞
Operating temperature +16Celsius to +32Celsius Relative humidity no more than 85%
Storage temperature -20Celsius to +50Celsius Relative humidity no more than 95%
Power supply AC110~220V 50~60Hz
Measurement distance 3~5m
Digital output 14bit
Interface USB 2.0 connect to PC
Image display 256 color CSTN
Application software application software is stored in CD. Double click install. Exe in CD, and setup program will run automatically. Application software is running under Windows 2000/XP/98
Drive software USB interface driver (specified)
Computer configuration P4 CPU / 256M RAM / Hard disk / 17" CRT Monitor / CD-ROM / Keyboard / Mouse Motherboard must support USB 2.0