Product Main

Specifications

Access control board with RS485 for single door

Model No. ACB-R01
Product Name Single Door Access Control Panel
Unit Size 160mm *106mm
Unit Packing Way Brown box
Unit Packing Size 21x13.8x5.5cm
Accessories User Manual, warranty card
Conventional Function offline operation; real time supervision; photo display; mass storage; flexible user privilege setup; remote unlocking; multi-user supervision; quick setting; convenient checking and query; revisable and printable report form; report form;report can be exported to excel file; card+password unlocking; alarm for long time unclosing;alarm for invalid card swiping; first card unlocking;alarm for illegal break in; unlocking at definite time; e-map etc

Professional function for professional users such as bank,cash house, telecom station, power supply station,prison and plice station: interface locking; intimidation alarm; integrated fire control;anti-passback and anti-tail; interlocking;multi-card unlocking; emergency double locking; in door population checking; unlocking based on internal and external validation.
  all-in-one-card management system nomal shift and multi-shifts time attendance management system; fixed ration dining management system; meeting attendance management system; online patrol management system and security alarm management system.
Parameter
  Communication RS232 RS485 no need jumper and adaptive 9600 bps
  English Software supportable database: Access and SQL
  Description Control 1 door, get in and out door by swiping card, or get in by swiping card and get out door by button
  Power Supply 12VDC 4-7A
  Power Consumption of Circuit Board Less than 100mA
  Input Format of Reader Wiegand 26 (All card reader with compatible protocol, such as Motorola , HID, EM , Mifare one etc)
  Quantity of Readers 2pcs
  Door Controlled 1
  Door opening time extending setting 1-600 seconds(adjustable)
  Max q ' ty of controller N*256PCS
    Remark: N denotes q ' ty of computer serial prot or q ' ty of 485hub port, support 256pcs ports
  Operation Temperature minus 40℃-70℃
  Operation Humidity 10-90 % RH , No Condensation
  Q ' ty of users 20,000 Users
  Q ' ty of Event Buffers(offline) 100,000 event buffers
  Power interruption protection measure High Speed Memory, Records never lose
  Max Distance from Reader to Controller 100m (suggestion distance 80m)
  Max Distance between Controllers RS232: Communication Distance less than 13m, suggestion distance is 3m or less
RS485: bus line max length 1200m, suggestion length 1000m or less, if expansion device added, the distance could be 3000m
TCP/IP: Depends on net coverage area
  Collocations PCB board, case, power, power line, serial port communication line, software, manual, certificate, key(2pcs), carton
  Alarm for long time door open, ilegal break in, intimidate Yes
  Fire and alarm linkage If no connection with the expansion board, only has software interface alarm, and drive the computer speaker. If connected with expansion board, is able to alarm by hardware, if connected with strengthened expansion board, then is able to Security alarm
  Complsive open and close door at long time Yes
  Open door in remote distance Yes
  Inter block No
  Anti pass back and tail Yes
  Multi-card open door Yes
  Open long time at specified time Yes
  Electronic map Yes
  Urgency locking Yes
  First card unlocking Yes
  Unlock based on internal and external validation Yes
  Keypad (card+passwor, supper password) Yes