Introduction
Cummins series diesel generating set ,powered by Cummins engine, it enjoys the features of high reliability, easy maintenance, long continuous running hours and ideal for port, railway, industrial and mining.
Engine data
|
|
Manufacturer / Model
|
DCEC Cummins 6CTA8.3-G2,4-cycle
|
Air Intake System
|
Turbo, Water/Air Cooling
|
Fuel System
|
PB/W type fuel pump
|
Cylinder Arrangement
|
6 in line
|
Displacement
|
8.3L
|
Bore and Stroke
|
114×135(mm)
|
Compression Ratio
|
17/1
|
Rated RPM
|
1500rpm
|
Max. Standby Power at Rated RPM
|
180KW/244HP
|
Governor Type
|
Electronic
|
Alternator Data
Manufacturer
|
Stamford/ Leroy Somer etc
|
Number of Phase
|
3
|
Connecting Type
|
3 Phase and 4 Wires, “Y” type connecting
|
Number of Bearing
|
1
|
Power Factor
|
0.8
|
Protection Grade
|
IP23
|
Altitude
|
≤1000m
|
Exciter Type
|
Brushless, self-exciting
|
Insulation Class, Temperature Rise
|
H/H
|
Telephone Influence Factor (TIF)
|
<50
|
THF
|
<2%
|
Voltage Regulation, Steady State
|
≤±1%
|
Alternator Capacity
|
160KVA
|
Alternator Efficiencies
|
92.3%
|
Air Cooling Flow
|
0.514m3/s
|
Generating set data
Voltage Regulation
|
≥±5%
|
Voltage Regulation, Stead State
|
≤±1%
|
Sudden Voltage Warp (100% Sudden Reduce)
|
≤+25%
|
Sudden Voltage Warp (Sudden Increase)
|
≤-20%
|
Voltage Stable Time (100% Sudden Reduce)
|
≤6S
|
Voltage Stable Time (Sudden Increase)
|
≤6S
|
Frequency Regulation, Stead State
|
≤5%(adjustable)
|
Frequency Waving
|
≤0.5%
|
Sudden Frequency Warp (100% Sudden Reduce)
|
≤+12%
|
Sudden Frequency Warp (Sudden Increase)
|
≤-10%
|
Frequency Recovery Time (100% Sudden Reduce)
|
≤5S
|
Frequency Recovery Time (Sudden Increase)
|
≤5S
|
operation
After diesel generator installed, you can put into power, before each start, at least the following items should be checked
1.whether unit surface and around has debris
2.keep the into and exhaust channel of the engine room is smooth
3.the cooling liquid tank is normal
4.the air filter indicator directs normal
5.lubricating oil level is within normal range
6.the fuel valve is open, the supply of fuel to engine is normal
7.battery cables are connected correctly
8.power load device is ready,when the generator directly with the load, breaking the air switch before start.
2.keep the into and exhaust channel of the engine room is smooth
3.the cooling liquid tank is normal
4.the air filter indicator directs normal
5.lubricating oil level is within normal range
6.the fuel valve is open, the supply of fuel to engine is normal
7.battery cables are connected correctly
8.power load device is ready,when the generator directly with the load, breaking the air switch before start.