Product Main

Specifications

Introduction  
Cummins series diesel generating set ,powered by Cummins engine, it enjoys the features of high reliability, easy maintenance, long continuous  running hours and ideal for port, railway, industrial and mining.
Engine data
 
Manufacturer / Model
DCEC Cummins  6CTA8.3-G2,4-cycle
Air Intake System
Turbo,  Water/Air Cooling
Fuel System
 PB/W type fuel pump
Cylinder Arrangement
6 in line
Displacement
8.3L
Bore and Stroke
114×135(mm)
Compression Ratio
17/1
Rated RPM
1500rpm
 
Max. Standby Power at Rated RPM
180KW/244HP
Governor Type
 Electronic
 
Alternator Data
Manufacturer
Stamford/ Leroy Somer etc
Number of Phase
3
Connecting Type
3 Phase and 4 Wires, “Y” type connecting
Number of Bearing
1
Power Factor
0.8
Protection Grade
IP23
Altitude
≤1000m
Exciter Type
Brushless, self-exciting
Insulation Class, Temperature Rise
H/H
Telephone Influence Factor (TIF)
<50 
THF
<2%
Voltage Regulation, Steady State
≤±1%
Alternator Capacity
160KVA 
Alternator Efficiencies
92.3% 
Air Cooling Flow
0.514m3/s
 Generating set data
Voltage Regulation
≥±5% 
Voltage Regulation, Stead State
≤±1%
Sudden Voltage Warp (100% Sudden Reduce)
≤+25%
Sudden Voltage Warp (Sudden Increase)
≤-20%
Voltage Stable Time (100% Sudden Reduce)
≤6S
Voltage Stable Time (Sudden Increase)
≤6S
Frequency Regulation, Stead State
≤5%(adjustable)
Frequency Waving
≤0.5%
Sudden Frequency Warp (100% Sudden Reduce)
≤+12% 
Sudden Frequency Warp (Sudden Increase)
≤-10%
Frequency Recovery Time (100% Sudden Reduce)
≤5S
Frequency Recovery Time (Sudden Increase)
≤5S 
 operation
After diesel generator installed, you can put into power, before each start, at least the following items should be checked
1.whether unit surface and around has debris
2.keep the into and exhaust channel of the engine room is smooth
3.the cooling liquid tank is normal
4.the air filter indicator directs normal
5.lubricating oil level is within normal range
6.the fuel valve is open, the supply of fuel to engine is normal
7.battery cables are connected correctly
8.power load device is ready,when the generator directly with the load, breaking the air switch before start.