----BS-9083N Series Ni-Cd/Ni-MH cell formation and grading equipment
Specifications:
|
Model
|
BS-9083N-2A
|
BS-9083N-3A
|
|
Number of test channels
|
512 channels, every channel has independent constant current source
|
|
|
battery holder
|
Adjustable cylindrical cell holder with Four- wire spring fixture
|
|
|
Adjustable range of fixture height(mm)
|
10 ~ 90
|
|
|
Distance between fixtures (mm)
|
35
|
|
|
Charge and discharge current range(A)
|
0.01 ~ 2
|
0.01 ~ 3
|
|
Current measurement accuracy
|
±(0.1% FS + 0.1% RD)
|
|
|
Current resolution (mA)
|
1
|
|
|
Voltage measurement range(V)
|
0.1 ~ 5
|
|
|
Voltage measurement accuracy
|
±(0.1% FS + 0.1% RD)
|
|
|
Voltage resolution(mV)
|
1
|
|
|
Voltage range of tested cell(V)
|
0.8 ~ 2
|
|
|
Time measurement range(min/ step)
|
3000
|
|
|
Time measurement accuracy
|
±0.1%
|
|
|
Maximum steps number
|
16
|
|
|
Grading mode
|
capacity, time, capacity plus curve, time plus curve, capacity plus voltage
|
|
|
Universality
|
It can be upgraded to lithium ion cell test equipment by changing inner connection mode
|
|
|
AC power input
|
3¢AC380V±5% 50Hz
|
|
|
Dimensions (mm)
|
1450 mm wide ×500 mm deep ×1800 mm high
|
|
BS-9083N Series Ni-Cd/Ni-MH cell formation and grading equipment
Features:
l It is designed for use in the formation and grading of Ni-Cd/Ni-MH rechargeable cells.
l Each channel owns the separated constant current-constant voltage circuit, smooth transition from constant current to constant voltage, so channels will not influence to each other.
l Omit relay and achieve noncontact control, improves stability greatly.
l Modular design ensures reliability and easy maintenance.
l Automatic adjust charge current, discharge current and constant voltage for easy operation
l Each cabinet has 16 groups, as it is bilateral structure, with 8 groups on each side and 32 cells each group, so the whole cabinet can test 512 cells.
l It provides five grading modes: capacity grading, time grading, capacity plus curve grading, time plus curve grading, capacity plus voltage grading.
l Testing process allows16 steps parameters and store 16 curves of cells charge and discharge.
l Every channel has a LED indicator which shows holding state of cell.
l Communication: RS-485, baud rate: 57.6Kbit
l Every computer can control 1~10 set(s) of equipment at the same time.
l It can protect data when power failure and continue to run when power is restored.
l The equipment can work off-line.
l It is easy to change Ni-Cd/Ni-MH cell formation & grading equipment to lithium ion cell formation & grading equipment.