Product brief introduction
 
The DDS5558 type single-phase electronic watt hour meter adopt exclusive use LSI, the device typifying new periphery component, simple structure, high reliability, low power consumption, long life etc, is suitable for the single-phase AC active electric energy with rated frequency of 50Hz. The performance is in conformity with the technical requirements for Single-phase Electronic Watt-hour Meter stipulated in GB/T17215.321 2008 Class I and 2 Static AC Active Watt-hour Meter standard
 
Function and Feature
1.Measure active electric energy, do not need calibrate for long-term operation
2.Adopt dedication meter age chip ADE7755
3.Adopt lasted electricity dedication integrated circuit including digital multiplier overseas, greatly improved dynamic working range of Meter, making lO multiple actual overload, Have good mistake linearity in the range of 5%lb~lmax
4.Few periphery component, simple structure, low power consumption
5.Adopt high reliability and long life electronic component, so the Meter assume 6.feature of high reliability and long life
1)Way of display register, LCD, digital tube
2)Remote interruption of power supply function
3)Output interface RS 485.

Main technical data:

Rated current(A)
1.5/6A 2.5/10A 5/20A 10/40A 15/60A 20/80A 30/100A
Rated Voltage(V) 
220 or 240
Rated Frequency(Hz)
50or60
Accuracy Class
  class1 or class 2