Product Main

Specifications

GD-100 Dual Output Switching Power Supply

Features


- High efficiency,high reliability
- AC input range selected by switch
- 100% full load burn-in test
- Protection: Short circuit/Over load
- Cooling by free air convection
- Fixed switching frequency at 25KHz
- 1 year warranty
- Dimensions: 199*98*38mm(L*W*H)

MODEL GD-100A GD-100B GD-100C
CH1 CH2 CH1 CH2 CH1 CH2
OUTPUT
DC Voltage
5V 12V 5V 24V 12V 24V
Voltage Tolerance
±2% ±6% ±2% ±7% ±2% ±7%
Rated Current
15A 2A 15A 1A 4A 2A
Current Range
1-15A 0.3-2A 1-15A 0.2-1A 0.2-2A 0.2-2A
Rated Power
99W 99W 96W
Ripple & Noise
100mVp-p 120mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p
DC Adjustment Range
CH1: -5%, +10%
Setup, Rise, Hold Time
200ms,50ms,20ms at full load
INPUT
Voltage Range
85~132 VAC / 180~264VAC 47~63 Hz; Selected by switch 255~370VDC
AC Current
2.4A/115 V 1.2A/ 230 V
Efficiency
73%
Inrush Current
Cold start 30A/115V 60A/230V
Leakage Current
<1mA/240VAC
PROTECTION
Over Load
105%~165%
Protection: Shut down o/p voltage, re-power on to recover
ENVIRONMENT
Working Temp., Humidity
-10℃~+50℃; 20%~90 %RH
Storage Temp., Humidity
-20℃~+85℃; 10%~95 %RH
Vibration
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes
SAFETY
Withstand Voltage
I/P-O/P:1.5KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC
Isolation Resistance
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
STANDARD
Safety Standard
Design refer to UL1012
OTHERS
Weight
0.62Kg
Packing
30pcs/19Kg/0.99CUFT
NOTE
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.