GD-100 Dual Output Switching Power Supply
Features
- High efficiency,high reliability
- AC input range selected by switch
- 100% full load burn-in test
- Protection: Short circuit/Over load
- Cooling by free air convection
- Fixed switching frequency at 25KHz
- 1 year warranty
- Dimensions: 199*98*38mm(L*W*H)
Features
- High efficiency,high reliability
- AC input range selected by switch
- 100% full load burn-in test
- Protection: Short circuit/Over load
- Cooling by free air convection
- Fixed switching frequency at 25KHz
- 1 year warranty
- Dimensions: 199*98*38mm(L*W*H)
| MODEL | GD-100A | GD-100B | GD-100C | ||||
| CH1 | CH2 | CH1 | CH2 | CH1 | CH2 | ||
| OUTPUT |
DC Voltage
|
5V | 12V | 5V | 24V | 12V | 24V |
|
Voltage Tolerance
|
±2% | ±6% | ±2% | ±7% | ±2% | ±7% | |
|
Rated Current
|
15A | 2A | 15A | 1A | 4A | 2A | |
|
Current Range
|
1-15A | 0.3-2A | 1-15A | 0.2-1A | 0.2-2A | 0.2-2A | |
|
Rated Power
|
99W | 99W | 96W | ||||
|
Ripple & Noise
|
100mVp-p | 120mVp-p | 100mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | |
|
DC Adjustment Range
|
CH1: -5%, +10%
|
||||||
|
Setup, Rise, Hold Time
|
200ms,50ms,20ms at full load
|
||||||
| INPUT |
Voltage Range
|
85~132 VAC / 180~264VAC 47~63 Hz; Selected by switch 255~370VDC
|
|||||
|
AC Current
|
2.4A/115 V 1.2A/ 230 V
|
||||||
|
Efficiency
|
73%
|
||||||
|
Inrush Current
|
Cold start 30A/115V 60A/230V
|
||||||
|
Leakage Current
|
<1mA/240VAC
|
||||||
| PROTECTION |
Over Load
|
105%~165%
|
|||||
|
Protection: Shut down o/p voltage, re-power on to recover
|
|||||||
| ENVIRONMENT |
Working Temp., Humidity
|
-10℃~+50℃; 20%~90 %RH
|
|||||
|
Storage Temp., Humidity
|
-20℃~+85℃; 10%~95 %RH
|
||||||
|
Vibration
|
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes
|
||||||
| SAFETY |
Withstand Voltage
|
I/P-O/P:1.5KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC
|
|||||
|
Isolation Resistance
|
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
|
||||||
| STANDARD |
Safety Standard
|
Design refer to UL1012
|
|||||
| OTHERS |
Weight
|
0.62Kg
|
|||||
|
Packing
|
30pcs/19Kg/0.99CUFT
|
||||||
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. |
||||||

