Product Main

Specifications

XLPE Insulated Wire
STYLE: UL 3266
UL LEADER FILE NO: E186XXX
CSA MASTER CONTRACT: 204XXX
Rated temperature: 125
Rated voltage: 300V
Reference standard: UL758, UL1581, CSA C22.2
Solid or stranded, tinned or bare copper conductor 30-10AWG
XLPE insulation, comply with RoHS environmental standard
Passes UL VW-1 and CSA FT2 flame test
Uniform insulation thickness to ensure easy stripping and cutting
For motor leads internal wiring of appliance
MARKING
AWM E186XXX STYLE 3266 AWG XLPE 125 300V I A (LOGO) ---- 204XXX CSA CL1252 AWM 125 300V FT2

Conductor Insulation Max. cond.
Resistance
(Ω /Kft, 20)
Standard
Put-up
AWG (No/mm) Dia.
(mm)
Thickness
(mm)
O. D.
(mm)
ft/coil m/coil
26 7/0.16 0.48 0.38 1.20± 0.1 45.2 2000 610
24 11/0.16 0.61 1.40± 0.1 29.3
22 17/0.16 0.76 1.55± 0.1 16.7
20 21/0.178 0.94 1.80± 0.1 10.5
18 16/0.254 1.16 2.10± 0.1 6.52
16 26/0.254 1.49 2.30± 0.1 4.18
14 41/0.254 1.87 2.70± 0.1 2.62
12 65/0.254 2.36 3.25± 0.1 1.65 1000 305
10 105/0.254 3 4.25± 0.1 1.04
Note: a single conductor structure is shown in tableSeries outside the structure and specifications of supply and demand can be agreed.