High Sensitivity Mulit-jet Cold(Hot) Water Meter
Model: LXS-15~25
Serial number: SJ09015
Description
Feature
1.High sensitivity: start-up flow less than or equals to 2L/h
2.Model choice: Makes each type water meter
3.Measuring accuracy conform to ISO 4064 Class B Standard
Description
This range of water meter is used to measure the total quantity of cold potable water which consumed in household or a resident unit,passing through the pipelione.
Working condition
Cold water temperature: less than or equals to 40 centigrade
Hot water temperature:less than or equals to 90 centigrade
Working pressure:less than or equals to 1MPa
Main technical data
Meter Size
(mm) |
Class
class |
Overload Flow
|
Nominal Flow
|
Transitional Flow
|
Min Flow
|
Starting flow
|
Min Reading
|
Max Reading
|
m3/h
|
l/h
|
m3
|
||||||
15
|
B
|
3
|
1.5
|
120
|
30
|
2.0
|
0.0001
|
99999
|
20
|
B
|
5
|
2.5
|
200
|
50
|
2.0
|
0.0001
|
99999
|
25
|
B
|
7
|
3.5
|
280
|
70
|
2.0
|
0.0001
|
99999
|
Dimensions and weight
Meter Size
(mm) |
Length L
|
Height H
|
Width B
|
Connecting Thread
D |
Weight
KG |
mm
|
|||||
15
|
165
|
104
|
90
|
G3/4B
|
1.3
|
20
|
190/195
|
106
|
99
|
G1B
|
1.5
|
25
|
265/225
|
114
|
103
|
G 11/4B
|
2.3
|