Applications
1) WDM transmission
2) WDM based ADM
3) Metro and long haul net works
4) Wavelength selective routing
5) Optical signal processing
1) WDM transmission
2) WDM based ADM
3) Metro and long haul net works
4) Wavelength selective routing
5) Optical signal processing
Agilecom's dense wavelength division mux/demultiplexer athermal arrayed waveguide grating modules are part of a series of high performance products based on silicon planar technology and a unique athermal packaging design requiring no electrical power, software or temperature control for a completely passive DWDM solution. This product range offers a combination of very low loss and high channel isolation along with long term reliability. Each module can perform mux and demux functions, both c-band devices are available with flat top spectral response. Custom frequency grids, fiber types and connectorisation options are also available.
Parameter | Specifications | |||
Gaussian/Flat top | ||||
ITU Passband (GHz) | ± 12.5 | |||
Channel Spacing (GHz) | 100GHz/50GHz | |||
Number Of Channels | 16, 32, 40, 48 or customize | |||
Wavelength Accuracy (nm) | 0.05 | |||
Insertion Loss (dB) | Max | 5.0db | ||
-1dB Passband (nm | Max | 0.24 | ||
-3dB Passband (nm) | Max | 0.43 | ||
|
Min | 25 | ||
|
Min | 30 | ||
Total isolation | Min | 22 | ||
Passband Ripple (dB) | Max | 1.0 | ||
Polarization Dependent Loss (dB) | Max | 0.4 | ||
Directivity (dB) | Max | 0.8 | ||
Return Loss (dB) | Min | 45 | ||
Polarization Mode Dispersion (ps) | Max | 0.5 | ||
Power Handling (mW) | Max | 300 | ||
Drive Voltage(Heater) (V) | Typ | 5.0 | ||
Drive Current(Heater) (A) | Typ | 2.0 | ||
Fiber Type | 9/125 um SMF-28e or customer appoint | |||
Operating Temperature (º C) | -5 ~ +70 | |||
Storage Temperature (º C) | -40 ~ +85 | |||
Package Dimension (mm) (LxWxH) | 150x 65x 16 |