Product Main

Specifications

Detailed description of pipe joints
  Description:
the dimension of the diagram is calculated by millimeter.
flexible embedded waterproofing casing applies to the building which requires decreasing vibration and totally waterproofing at the pipe passing regions.
brushing primer over the theca evenly after the sleeve finished (the primer could be minium or adhesive bitumen primer) and covering antisepticise on request.
it must be concrete-wall where the sleeve passing through. The range of the fluid concrete ought to be 200mm wider than the fins’ diameter and the sleeve should be concreted tightly inside the wall.
Installation data of S312
Rigid Coupling Sleeve
S312-G
Length(Wall Thickness)
External Outer Diameter
External Ring Diamete
A
B
A
B
200
60
60
225
225
200
73
73
238
238
200
89
93
251
251
200
108
118
280
289
200
133
143
301
315
200
159
169
324
340
200
219
220
394
394
200
273
271.6
446
446
200
325
322.8
498
498
200
377
374
567
567
200
426
425.6
621
621
200
480
476.8
671
671
200
530
528
720
720
200
630
630.8
822
810
200
720
733
911
924
200
820
836
1011
1027
200
920
939
1113
1132
200
1020
1041
1213
1234
Notes:1, Please give clear indication of type, wall thickness and external diameter.
         2, The big DN size can be adjusted in accordance with requirement of users.