SV-QY full
flow smoke meter, which can test exhaust visible pollutants from auto bike and moped, is an intelligent portable instrument. This kind of instrument makes use of advanced test technology and abroad advanced test parts. It can apply for environment protection section, automobile test station, automobile manufacture, auto bike repair station and so on
flow smoke meter, which can test exhaust visible pollutants from auto bike and moped, is an intelligent portable instrument. This kind of instrument makes use of advanced test technology and abroad advanced test parts. It can apply for environment protection section, automobile test station, automobile manufacture, auto bike repair station and so on
Features:
1. Split type design made the control unit apart from the test unit.
2. SV-QY smoke meter has a large LCD display screen with whole English menu. There are two sets of data: opacity and optical absorption
3. The function of auto speed up and instant test can auto deal with the tested data and display testing result.
4. Pre-heat time is 10 minutes and automatically adjusts to zero.
5. Test unit use branch technology can test exhaust from auto bike. By the use of "Constant Temperature Control System" can prevent condensation and avoid the impact for the measurement of accuracy by temperature shift.
6. It can be connected with computer through RS-232 plug, and there is a mini printer inside.
7. The instrument performance meets the requirement of GB19758-2005.
8. Digital time display.
9. Automobile plate input function can input the headline and plate number of province, city and district. For vehicle match for the test result, when using it, customers can check and transfer allocate the test result.
10. It can set and regulate the stroke and cylinder by users’ actual need.
Main Technical Parameters
1.Measurement range: Opacity N: 0-99.9%
Coefficient of light-absorption K: 0-135.98m-1
Rated speed R: 100-9999rpm
2.Resolution: Opacity N: 0.1%
Coefficient of light-absorption K: 0.01m-1
Rated speed : ±1rpm
3.Indicated error: opacity N: ±1.0%(absolute error)
4. The allowable error for indication: opacity: ±1.0 %( absolute error)
5.Effective path length of light ray: 50.8mm
6.Preheat time: 10min
7. Power: AC220V±1Hz