F1603 CDMA2000 1X EVDO MODEM is a kind of cellular terminal device that provides SMS and dial-up function by public EVDO network.
It adopts high-powered industrial cellular module and supports RS232 port that can conveniently connect one device to a cellular network, allowing you to connect to your existing serial device.
It has been widely used on M2M fields, such as intelligent transportation, smart grid, industrial automation, telemetry, finance, POS, water supply, environment protection, post, weather, and so on.
Cellular Specification
|
Item
|
Content
|
|
Cellular Module
|
Industrial cellular module
|
|
Standard and Band
|
CDMA2000 1X EVDO Rev A 800MHz,800/1900MHz(optional),
450MHz (optional)
CDMA2000 1X RTT, IS-95 A/B
|
|
Bandwidth
|
Download speed:3.1Mbps, upload speed:1.8Mbps
|
|
TX power
|
<23dBm
|
|
RX sensitivity
|
<-104dBm
|
Interface type
|
Item
|
Content
|
|
Serial
|
1 RS232 port, 15KV ESD protection
Data bits: 5, 6 ,7, 8
Stop bits: 1, 1.5, 2
Parity: none, even, odd, space, mark
Baud rate: 110~230400 bps
|
|
Indicator
|
“Power”, “ACT”, "Online”
|
|
Antenna
|
Standard SMA female interface, 50 ohm, lighting protection(optional)
|
|
SIM/UIM
|
Standard 3V/1.8V user card interface, 15KV ESD protection
|
|
Power
|
Standard 3-PIN power jack, reverse-voltage and over voltage protection
|
|
|
|
Power supply
|
Item
|
Content
|
|
Standard Power
|
DC 12V/0.5A
|
|
Power range
|
DC 5~35V
|
|
Consumption
|
<200mA (12V)
|
Physical Characteristics
|
Item
|
Content
|
|
Housing
|
Iron, providing IP30 protection
|
|
Dimensions
|
91x58.5x22 mm
|
|
Weight
|
205g
|
Environmental Limits
|
Item
|
Content
|
|
Operating Temperature
|
-25~+65ºC (-13~+149℉)
|
|
Extended Operating Temperature
|
-30~+75ºC (-22~+167℉)
|
|
Storage Temperature
|
-40~+85ºC (-40~+185℉)
|
|
Operating Humidity
|
95% ( unfreezing)
|