Product Main

Specifications

Product Description:
1)  Tinned, annealed, stranded or solid copper conductor.
2)  XL-PVC insulation.
3)  Rated temperature: 80℃. Rated voltage: 150Volts.
4)  Uniform thickness of wire to ensure easy stripping and cutting.
5)  Passes UL VW-1 & CSA FT1/FT2 vertical flame test.
6)  Resistant to heat, cold, abrasion, tinned flexiblity, cut-through, oil, ect.
7)  Executive Standard: UL758, UL1581, CSA22.2.
Applications:
1)  For electric Cookers, Hair dryers, incoming wires of transformer, air-conditioners, lights fixture,electric ovens, ect.

UL Style & CSA Type Conductor Insulation
Thickness
Overall
Diameter
Standard Put-up Conductor
Resistance at 20℃
AWG No/mm mm mm Ft/coil M/Coil Ω/KM
UL1429
(Stranded)
30 7/0.100 0.23 0.80 2000 610 381.00
28 7/0.127 0.23 0.90 2000 610 239.00
26 7/0.160 0.23 1.00 2000 610 150.00
24 11/0.160 0.23 1.10 2000 610 94.20
22 17/0.160 0.23 1.30 2000 610 59.40
20 21/0.178 0.23 1.50 2000 610 36.70
18 34/0.178 0.23 1.80 2000 610 23.20
16 26/0.250 0.23 2.10 2000 610 14.60
UL1429    (Top-coated) 30 7/0.100 0.23 0.80 2000 610 381.00
28 7/0.127 0.23 0.90 2000 610 239.00
26 7/0.160 0.23 1.00 2000 610 150.00
24 7/0.200 0.23 1.10 2000 610 94.20
22 7/0.250 0.23 1.25 2000 610 59.40
UL1429     (Solid) 26 1/0.404 0.23 0.90 2000 610 150.00
24 1/0.511 0.23 1.00 2000 610 94.20
22 1/0.643 0.23 1.15 2000 610 59.40
20 1/0.813 0.23 1.35 2000 610 36.70
18 1/1.024 0.23 1.55 2000 610 23.20