Good Quality Solar Collector 58*1200*30 tubes
1. Working principle of high pressure solar heater: Utilizes the alternative
Absorption coating on the inner surface of the vacuum tube, from the High-temperature environment super conduction tubes, leads the heat to the water tank, and produces hot water
2. Easy to use, also convenient to install
3. Can be put in the courtyard, on the roof or balcony
4. Inlet water hole connects to the tap water, and the outlet hole connects to the tap water, and the outlet hole produces pressure hot water directly.
1. Working principle of high pressure solar heater: Utilizes the alternative
Absorption coating on the inner surface of the vacuum tube, from the High-temperature environment super conduction tubes, leads the heat to the water tank, and produces hot water
2. Easy to use, also convenient to install
3. Can be put in the courtyard, on the roof or balcony
4. Inlet water hole connects to the tap water, and the outlet hole connects to the tap water, and the outlet hole produces pressure hot water directly.
Technical Data of Heat pipe collector | |||
Production Model | JX-58 | JX-58 | |
Numbers of tube(pcs) | 30 | 20 | |
Absorber area approx.(m2) | 2.439 | 1.626 | |
Gross size(m) | 1.99*2.1*0.154 | 1.99*1.4*0.154 | |
Weight Empty(kg) | 93.5 | 63 | |
Hydraulic Connections | G3/4" male thread | ||
Loading qty in 20 GP/40GP/40HQ | 63/130/145 | 90/185/210 | |
Fluid volume(L) | 1.7 | 1.2 | |
Min. volume flowrate per collector(L/H) | 108 | 72 | |
Rated volume flowrate per coll.(L/H) | 180 | 120 | |
Max. volume flowrate per collector(L/H) | 1200 | 1200 | |
Maximum operation pressure(Bar) | 6 | ||
Test pressure(Bar) | 9 | ||
Heat transfer fluid | Anti-freeze Fluid (Water-Glycol) | ||
Max.working temp | 250C | ||
hot water(L/Day) | 240C | 160 | |
ΔT | 35C(Radiation>=800w/m2.day) | ||
Collector efficiency | 76.4% 76.2% | ||
Medium | Pure water | ||
Start-up Temperature of heat pipe | <=30C | ||
warranty | 5 years | ||
Mateial Details | |||
Produciton Model | FD-58 | ||
Flow type | Heat pipe | ||
Heat pipe material | T2 copper | ||
Heat pipe size | Top 14* 1mm; Body 8* 0.7mm | ||
Tube diameter | φ47/1500mm or φ58/1800mm | ||
Solar vaccum glass tube | High boron-silicon | ||
Coating of absorber on glass tube | Al-N-Al,Copper,Stainless steel | ||
fins around heat pipe | single long Aluminum(1.68m) | ||
Manifold pipe material | TP2 copper ( 35x0.8mm) | ||
Manifold casing material | 6063 Aluminum alloy frame(1.8mm) | ||
Insulation material in manifold caseing | Glass fiber | ||
Thickness of insulation(mm) | 45 | ||
Density of insulation (kg/m3) | 90 | ||
Frame material | 6063 Aluminum alloy frame(3mm) | ||
Frame and manifold casing finish | Black Powder coated | ||
Sealing Materials | EPDM |