x-ray ndt detector, x-ray pipeline crawler, inspection equipment, tube creeper, tube crawler , x-ray crawling, pipeline detector, pipeline crawler x-ray.
Micro-wave video X-ray pipeline crawler
Features:
1 X-ray Generator system has a regulatory function of KV with large diameter and thick walled tube has the regulatory function. Tran illumination to ensure the X-ray film and degree of consensus.
2 Electronic speed control motor function, to achieve constant torque, constant current operation, could be 40 percent energy saving at the same time motor over current protection.
3 Automatically inspect the energy of battery. When the voltage of battery is not enough, the crawler will turn back in time .
4 It has various real-time function to protect the x-ray generator in case of meeting water, over-voltage, zero voltage, over-current, zero current, meeting barrier, antenna falling off, X-ray generator falling off, over temperature.
5 Instead of γ-source location, it adopts radio microwave video location, which is safer, more direct-viewing, and location-accurate.
6 It has a continuous contact with runner in order to show the inner situation clearly. e.g.: NDT Equipment fault, battery State LOW, over tempered inner pipeline, distance to the pipe mouth.
7 It has the automatic stop function, with no need of Real Time Monitoring.
Magnetic medium control X-ray pipeline crawler
Features:
1 Ease start, Low-state positioning. To ensure accurate positioning at the same time, extend equipment life.
2 Features with going through the welding machine, without impacting of the welding machine, good for normal work .
3 X-ray Generator system has a regulatory function of KV, Transillumination to ensure the X-ray film and degree of consensus.
4 Electronic speed control motor function, to achieve constant torque, constant current operation, could be 40 percent energy saving at the same time motor overcurrent protection.
5 Automatically inspect the energy of battery. When the voltage of battery is not enough, the crawler will turn back in time .
6 It has various real-time function to protect the x-ray generator in case of meeting water, over-voltage, zero voltage, over-current, zero current, meeting barrier, antenna falling off, X-ray generator falling off, over temperature.
Micro-wave video X-ray pipeline crawler
Features:
1 X-ray Generator system has a regulatory function of KV with large diameter and thick walled tube has the regulatory function. Tran illumination to ensure the X-ray film and degree of consensus.
2 Electronic speed control motor function, to achieve constant torque, constant current operation, could be 40 percent energy saving at the same time motor over current protection.
3 Automatically inspect the energy of battery. When the voltage of battery is not enough, the crawler will turn back in time .
4 It has various real-time function to protect the x-ray generator in case of meeting water, over-voltage, zero voltage, over-current, zero current, meeting barrier, antenna falling off, X-ray generator falling off, over temperature.
5 Instead of γ-source location, it adopts radio microwave video location, which is safer, more direct-viewing, and location-accurate.
6 It has a continuous contact with runner in order to show the inner situation clearly. e.g.: NDT Equipment fault, battery State LOW, over tempered inner pipeline, distance to the pipe mouth.
7 It has the automatic stop function, with no need of Real Time Monitoring.
Magnetic medium control X-ray pipeline crawler
Features:
1 Ease start, Low-state positioning. To ensure accurate positioning at the same time, extend equipment life.
2 Features with going through the welding machine, without impacting of the welding machine, good for normal work .
3 X-ray Generator system has a regulatory function of KV, Transillumination to ensure the X-ray film and degree of consensus.
4 Electronic speed control motor function, to achieve constant torque, constant current operation, could be 40 percent energy saving at the same time motor overcurrent protection.
5 Automatically inspect the energy of battery. When the voltage of battery is not enough, the crawler will turn back in time .
6 It has various real-time function to protect the x-ray generator in case of meeting water, over-voltage, zero voltage, over-current, zero current, meeting barrier, antenna falling off, X-ray generator falling off, over temperature.
Micro-wave video X-ray pipeline crawler
Main Technical specifications
Model
|
ZY-4C
|
ZY-3C
|
ZY-10C
|
Limit of applicable pipe-diameter (mm)
|
8.6"-14"
|
12.7"-28"
|
2
|
Outline dimension of creeping instrument (mm)
|
1600×260×240
|
1400×290×260
|
1430×340×290
|
Dimension of controller
(mm)
|
420×470×240
|
420×470×240
|
420×470×240
|
Weight (Kg)
|
30
|
67
|
90
|
Creeping Speed (m/min)
|
18
|
18
|
18
|
Location error (mm)
|
±5
|
±5
|
±5
|
Maxima climbing slope
|
30°
|
30°
|
40°
|
Ray radiation angle
|
360×40℃
|
360×40℃
|
360×40℃
|
Operate temperature
|
-20℃~75℃
|
-20℃~75℃
|
-20℃~75℃
|
Relative humidity
|
90%
|
90%
|
90%
|
No.
|
Item
|
Quantity
|
1
|
Climb car
|
1
|
2
|
X-ray Generator system
|
1
|
3
|
Command controller
|
1
|
4
|
Battery and cell box
|
1
|
5
|
Changer
|
1(120V)
|
6
|
Supporting plate
|
2
|
7
|
CCD camera
|
1
|
8
|
lifter slide
|
2
|
9
|
connecting cable
|
2
|
10
|
Short sleeves
|
adapting
|
11
|
Extension Shaft
|
adapting
|
Magnetic medium control X-ray pipeline crawler
Main Technical specifications
Model
|
ZY-4C
|
ZY-3C
|
ZY-10C
|
Limit of applicable pipe-diameter (mm)
|
8.6"-14"
|
12.7"-28"
|
2
|
Outline dimension of creeping instrument (mm)
|
1600×260×240
|
1400×290×260
|
1430×340×290
|
Dimension of controller
(mm)
|
190×170×110
|
190×170×110
|
190×170×110
|
Weight (Kg)
|
30
|
67
|
90
|
Creeping Speed (m/min)
|
18
|
18
|
18
|
Location error (mm)
|
±5
|
±5
|
±5
|
Maxima climbing slope
|
30°
|
30°
|
40°
|
Ray radiation angle
|
360×40℃
|
360×40℃
|
360×40℃
|
Operate temperature
|
-20℃~75℃
|
-20℃~75℃
|
-20℃~75℃
|
Relative humidity
|
90%
|
90%
|
90%
|
No.
|
Item
|
Quantity
|
1
|
Climb car
|
1
|
2
|
X-ray Generator system
|
1
|
3
|
Command controller
|
1
|
4
|
Battery and cell box
|
1
|
5
|
Changer
|
1(120V)
|
6
|
Supporting plate
|
2
|
7
|
CCD camera
|
1
|
8
|
lifter slide
|
2
|
9
|
connecting cable
|
2
|
10
|
Short sleeves
|
adapting
|
11
|
Extension Shaft
|
adapting
|