Product Main

Specifications

Key Features

  1. Multi-setting, according to input power condition user can be set as 1/1, 1/3, 3/1 or 3/3 system.
  2. It’s designed with modular structure and is made up of 1-10 modules
  3. It’s fitted with redundancy and can be upgraded according to your specific requirements
  4. N+X redundant technique, thus ensuring the reliable performance of the system
  5. The batteries can be shared
  6. The input THDI is not more than 5%
  7. Out modular UPS is environmentally friendly, small in size and light in weight.
  8. It’s easy to maintain. The module can be replaced optionally.
  9. System controller is used to carry out communications and diagnosis.
  10. Uses centralized static switch module

 

Applications
Data processing centers, computer systems, servers, communication systems, financial systems, servers, communication systems, financial systems, traffic systems, medical systems, and many other fields.

Technical Specifications of Modular UPS, MPS9330 5KVA-210KVA


Model

MPS9330  5KVA-210KVA

Single module capacity

5KVA  10KVA  15KVA

System capacity

5-210KVA

Rated frequency

50/60HZ

Input

Voltage range

380/400/415V  ±  20%

Input mode

3 phase 4 wire  + ground wire  / single phase 2 wire  + ground wire

Frequency range

45Hz-55H

Input power factor

≥  0.99

Total harmonic distortion

<3%

Slow start

>60sec

Output

Voltage accuracy

220V (Single phase) 380/400/415V (3 phase)

Frequency accuracy

When the frequency of utility power is 50HZ±2%, the output frequency of UPS follows the utility power frequency, and the phase difference is < 3°; when the frequency of utility power is beyond the 50Hz±0.2% or when the battery offers power, the output frequency is 50Hz±0.2%.

Power factor

0.8

Harmonic Distortion

Linear load ≤3% , non-linear load ≤5%

Current Crest Ratio

3:1

Whole unit efficiency

≥95% (AC power)  ≥98% (Battery Powered)

Current sharing accuracy

≤5%

Transfer time

0ms

Dynamic response transient range

Overload 10%~100% or 100%~10%, the output voltage is ≤2%

Load unbalance capability

Can endure 100% unbalanced load

DC

Input rated voltage

±384V

Input voltage range

345V~440V

Panel display

LCD

Chinese/English display UPS status, input voltage, output voltage, current, frequency, battery voltage, charge-discharge current value, fault and warning.

Working environment

Temperature

0~40℃

Humidity

0~95%, non-condensing

Storage temperature

-25℃~55℃

Altitude

≤ sea level 1500m

Noise(within 1m)

< 50dB

Physical property

Size W × D× H(mm)

600  ×  800  ×  2000

Follow standard of GB/IEC regulation: EMC:GB7260.2/IEC62040-2  GB/17626.2~5/IEC61000-4-2~5     SAFETY:GB4943
Note: Product specifications are subject to change without further notice.

UPS Modules

  1. Expansion easily according to demand to choose capacity collocate
  2. Online double conversion design, assure the output quality.
  3. Every module has digital and intelligent control separately.
  4. Every module just and independent UPS, can work independently.           
  5. Every module has independent charging system.
  6. Hot swappable, it ensure online maintenance.
  7. Standard dimension: 2U × 19 × 520mm


Static Switches

  1. Static Switch module for standard mode UPS.
  2. Work in SCR and AC contactor paralleled.
  3. High reliability, high overload ability: 100%, 1 second, 0ms transfer times.
  4. Function of self-diagnosis, interlock, protection


Communication & Monitoring Module

  1. System data.
  2. Modules data
  3. History log
  4. Work state display alarm and communication
  5. RS232 and RS422
  6. 8-pulse dry contacts output.
  7. SNMP adapter for standard mode.