Key Features
● True online double conversion technology
● Self test while start of the UPS
● Wide input voltage range
● Site wiring fault warning
● Zero transfer time
● On-battery power- on function
● Smart RS232 and Intelligent Slot Interface
● Sealed lead-acid, maintenance free battery
● Intelligent slot available
Applications
Servers, Data-center, Critical network devices, Sensitive electronic equipment, Telecom, Computer field, bank system, communications, postal service, power industry, medical treatment field, national defense field, chemical industry, and many other fields. It’s capable in offering solution for various utility power problems…
Technical Specifications of Online UPS HP9110E 1-3KVA
Model |
|
HP9110E 1KT |
HP9110E2KT |
HP9110E3KT |
HP9110E 1KT-XL |
HP9110E2KT-XL |
HP9110E 3KT-XL |
Capacity |
VA/W |
1KVA /0.7KW |
2KVA/1.4KW |
3KVA/2.1KW |
1KVA /0.7KW |
2KVA/1.4KW |
3KVA/2.1KW |
|
Rated Voltage |
220/230/240VAC |
|||||
Voltage Range |
120-300VAC |
||||||
Frequency Range |
50Hz:46-54Hz:; 60Hz::56-64Hz |
||||||
Power Factor |
0.97 |
||||||
Output |
Rated Voltage |
220/230/240×(1±2%)VAC |
|||||
Frequency |
Synchronization range (line mode);50 or 60×(1±0.2%)Hz(Battery mode) |
||||||
Waveform |
Sine wave |
||||||
Power factor |
0.7 or 0.8 Optional |
||||||
Voltage Distortion |
3% |
4% |
4% |
3% |
4% |
4% |
|
Overload Capability |
110%-150% for 30s; ≥150% for 200 ms |
||||||
Current Crest Ratio |
3:1 |
||||||
Connection |
IEC320*4 |
IEC320*6 |
IEC320*3& Terminal block |
IEC320*4 |
IEC320*6 |
IEC320*3& Terminal block |
|
Battery |
Type |
Sealed, maintenance-free lead-acid battery |
|||||
Quantity |
3 pieces |
8 pieces |
8 pieces |
Depends on the required back-up time |
|||
Backup time( Full load) |
5mins |
9mins |
5mins |
Depends on the required back-up time |
|||
Recharge Time |
5 hrs to 90% of capacity |
Depends on the required back-up time |
|||||
Transfer Time |
Zero transfer time |
Inverter to Bypass 4ms (Typical) |
|||||
Indicators |
LED Display |
UPS State, I/P & O/P voltage & Frequency, Battery Voltage, Battery Capacity, Loading, Temperature, History record. |
|||||
Audible larm |
|
Bypass, battery mode, low voltage, surge, fault |
|||||
Noise |
Within 1m |
<45dB |
<50dB |
<50dB |
<45dB |
<50dB |
<50dB |
Communication interface |
DB-9 Port |
RS-232 series interface |
|||||
Intelligent Slot |
Options: SNMP Card, AS400 Card or Winpower CMC/(USB Port) |
||||||
Environment |
Operating Temperature |
0-40℃ |
|||||
Operating humidity |
20-90% , non- condensing |
||||||
Weight |
Net W(kg) |
13 |
31.5 |
32 |
7 |
13.5 |
14 |
Size |
L×W×H(mm |
240×495 ×335 |
335×590 ×480 |
335×590 ×480 |
240×495 ×335 |
335×590 ×480 |
335×590 ×480 |
Follow standard of GB/IEC regulation: EMC:GB7260.2/IEC62040-2 GB/17626.2~5/IEC61000-4-2~5 SAFETY:GB4943
Note: Product specifications are subject to change without further notice