Product Main

Specifications

 An overview
 
 Electromagnetic flow meter is designed specifically for the water industry to meet the city's water supply to ensure the accurate calculation, the scene is widely used in places without power supply, such as urban water supply, sewage treatment, water conservancy and other industries.
 Electromagnetic flow meter specially designed sensor excitation system, and high-performance lithium battery-powered systems, and uses 16-bit AMD embedded processor power, with all-digital signal processing, measurement stability, high measurement accuracy, anti - Interference ability, and other features, automatic bi-directional flow measurement, on-site instantaneous flow of positive and negative cumulative total to show that self-diagnosis alarm FAULT Far GSM wireless data functions, the user through the powerful GSM / GPRS remote management software system can flow Far total wireless data storage functions.
 
2. The main technical parameters
 
■ Diameter: DN10-DN1200 DN150- DN3000(Also optional plug-in battery-powered electromagnetic flow meter)
■ Pressure: 0.6~4.0Mpa(Special pressure customizable)
■Precision: ±0.5%, ±1.0%
■ measuring range: 0 ~ 12m / s
■ Media Measurement (conductivity):> 20μs/cm
■ medium temperature: -10 ℃ ~ 100 ℃
■ ambient temperature: -10 ℃ ~ 60 ℃
■ humidity environment: ≤ 95% (relative humidity)
■ power supply: 3.6V/DC built-in lithium battery-powered, continuous working hours, more than 5 years
■ electrode materials: 316L stainless steel, HC, HB, titanium, tantalum, platinum / iridium alloy
■ lining materials: poly chloroprene rubber, polyurethane rubber, PTFE, F46, PFA
■ connections: flange type, plug-in, clip -
■ structure in the form of: a body divided body
■ level of protection: IP68
■ display: LCD large-screen liquid crystal display instantaneous flow of positive / reverse the cumulative total and prompt warning
■ output: the output pulse 0.0001-10m / p pulse width can be set to 20ms (passive output optocoupler)
■ means of communication: GSM wireless data transmission (packet in the form of text messages)
 
3. Appearance and size of the installation
 
Appearance and size of the installation (type flange connection) Figure 1, Table 1
 
Figure 1
 
 
 
Table 1
Diameter
(mm)
size of the installation(Pressure 1.6Mpa)
H
L
n
Φd
ΦD
D2
10
290
140
4
14
90
60
15
293
200
4
14
95
65
20
301
200
4
14
105
75
25
306
200
4
14
115
85
32
325
200
4
18
140
100
40
335
200
4
18
150
110
50
350
200
4
18
165
125
65
375
250
4
18
185
145
80
385
250
8
18
200
160
100
405
250
8
18
220
180
125
435
300
8
18
250
210
150
470
300
8
22
285
240
200
525
350
12
22
340
295
250
590
450
12
26
405
355
300
645
500
12
26
460
410
350
705
550
16
26
520
470
400
765
600
16
30
580
525
450
825
600
20
30
640
585
500
900
600
20
33
715
650
600
1025
600
20
36
840
770
700
1080
700
24
30
895
840
800
1200
800
24
33
1015
950
900
1300
900
28
33
1115
1050
1000
1415
1000
28
36
1230
1160
1200
1590
1200
32
36
1405
1340
 
4. Display
 
The instrument for large LCD screen LCD, two-line display, scheduled for the last 10 cumulative flow shows that the greatest value 9,999,999,999 display can be displayed alternate is, the reverse flow of the cumulative value of the schedule for the next five instantaneous flow shows that the largest display 99999 value can be displayed alternate is, the reverse flow of transient value and prompt report to the police.
Alarm Information
Corrective measures.
Air Traffic Alarm
Check whether the pipeline is full of fluid under test, to adjust air traffic control warning
Threshold adjustment factor and the air traffic control
Magnetically-shielded alarm system circuit
Check excitation output signal cable wiring and sensors
Alarm signal output short-circuit
Check signal cable wiring and sensor input
Check whether the appropriate scope of the range set to re-set range.
 
Limit traffic police
Check the output pulse frequency settings are appropriate, pulse frequency output
Pulse output limit alarm
Shall not exceed the maximum 1000HZ, re-set the maximum frequency
 
Check signal cable wiring and sensor input
Check whether the appropriate scope of the range set to re-set range.
 
Low-voltage battery alarm
Battery replacement
GSM forced to send police
GSM mandatory testing the use