Product Main

Specifications

Application
Can be used in the navigation system of tanks and military vehicles.
No.
Parameters
Performance Indicators
Units
EII
ME
1
Bias
≤±6
≤±6
mg
2
Scale Factor
1.1~1.5
1.1~1.5
mA/g
3
Second-order Nonlinearity
≤±30
≤±40
μg/g2
4
Bias Temp Coefficient
≤±30
≤±50
μg/℃
5
Scale Factor Temp Coefficient
≤±60
≤±70
ppm/℃
6
Bias Repeatability
≤30 (for 1 month)
≤30 (for 3~7 days)
μg
7
Scale Factor Repeatability
≤60(for 1 month)
≤60(for 3~7 days)
ppm
8
Second-order Nonlinearity Repeatability
≤20(for 1 month)
≤20(for 3~7 days)
μg/g2
9
Natural Frequency
≤800
≤800
Hz
10
Acceleration Range
≥±20
≥±20
g
11
Vibration
5g(20~2000Hz)
5g(20~2000Hz)
g, Hz
12
Shock
120g,4.5ms,1/2sin
120g,4.5ms,1/2sin
g, ms
13
Operating Temp
-45~+125
-45~+125
14
Resolution
≤5×10-6
≤5×10-6
g
15
Weight
≤80
≤80
g
Features: High precision, Large measurement range.