Product Main

Specifications

Application
Is suitable in the big measurement range and acceleration test system.
No.
Parameter
Performance Indicators
Units
EII
ME
M
1
Bias
≤±6
≤±6
≤±6
mg
2
Scale Factor
1.2±0.2
1.2±0.2
1.2±0.2
mA/g
3
Second-order Nonlinearity
≤±30
≤±40
≤±50
μg/g2
4
Bias Temp Coefficient
≤±30
≤±40
≤±50
μg/℃
5
Scale Factor Temp Coefficient
≤±60
≤±70
≤±80
ppm/℃
6
Bias Repeatability
≤50(for 1 month)
≤50(for 3~7 days)
≤50(day stability)
μg
7
Scale Factor Repeatability
≤50(for 1 month)
≤50(for 3~7 days)
≤50(day stability)
ppm
8
Second-order Nonlinearity Repeatability
≤30(for 1 month)
≤30(for 3~7 days)
≤30(day stability)
μg/g2
9
Natural Frequency
≤800
≤800
≤800
Hz
10
Acceleration Range
≥±20
≥±20
≥±20
g
11
Vibration
5g(20~2000Hz)
5g(20~2000Hz)
5g(20~2000Hz)
g, Hz
12
Shock
120g,4.5ms,1/2sin
120g,4.5ms,1/2sin
120g,4.5ms,1/2sin
g, ms
13
Operating Temp
-40~+125
-40~+125
-40~+125
14
Weight
≤40
≤40
≤40
g
Features: High precision and small volume.