Product Main

Specifications

Application
Uses in the high request of the environment and the precision situation,
its precision between I/C and I/D, but the same environment adaptiveness
with the II/B
No.
Parameter
Performance Indicators
Units
MJ
M
1
Bias
≤±7
≤±7
mg
2
Scale Factor
1.3±0.2
1.3±0.2
mA/g
3
Second-order Nonlinearity
≤±50
≤±50
μg/g2
4
Bias Temp Coefficient
≤±50
≤±80
μg/℃
5
Scale Factor Temp Coefficient
≤±60
≤±60
ppm/℃
6
Bias Repeatability
≤60(for 3~7 days)
≤60(day stability)
μg
7
Scale Factor Repeatability
≤60(for 3~7 days)
≤60(day stability)
ppm
8
Second-order Nonlinearity Repeatability
≤50(for 3~7 days)
≤50(day stability)
μg/g2
9
Acceleration Range
≥±10
≥±10
g
10
Vibration
5g(20~2000Hz)
5g(20~2000Hz)
g, Hz
11
Shock
120g, 4.5ms, 1/2sin
120g, 4.5ms,1/2sin
g, ms
12
Operating Temp
-45+125
-20~+125
c
13
weight
80
80
g
14
Features
 
           
Features: high precision, large range, Strong anti-vibration capability.