DTG-E6 with light weight, small size, and short start time, can be used in higher operating temperature, what now has been used in short-range missile strapdown attitude system, Oil drilling inclinometer tool and other products. Can be used in all kinds of strapdowm attitude system and the inertial measurement instrument with a higher operating temperature requirement.
N0.
|
Item
|
Specification
|
|
1
|
Performance
Parameter
|
Random Drift (1σ)
|
≤0.2°/h
|
Drift Stability (1σ)
|
≤0.3°/h
|
||
g-independent
|
≤15°/h
|
||
g-dependent
|
≤8°/h
|
||
Frequency Response
|
≥70Hz
|
||
2
|
Technological parameter
|
Power Supply(Three Phase)
|
205 Hz
|
10V
|
|||
Power Supply(Single Phase)
|
8 KHz
|
||
7 V
|
|||
Synchronous Speed
|
6,015
|
||
Synchronizing Time
|
≤10 S
|
||
Output Gradient
|
7~10 mv/’
|
||
Master torquer
|
19±3 Ω
|
||
Vice control torquer
|
2±0.5 Ω
|
||
3
|
Torquer scale factor
|
Master torquer
|
≥680 °/h/mA
|
Vice control torquer
|
≥10 °/h/mA
|
||
4
|
Max.Tracking Speed
|
≥100 °/s
|
|
5
|
Output Nonlinearity
|
≤0.5%
|
|
6
|
Life Time
|
≥5000
|
|
7
|
Operating Temperature
|
-20~+120℃
|
|
8
|
Shock Overload(8ms)
|
≥60 g
|
|
9
|
Physical Parameter
|
Dimension
|
Φ35.4×78 mm
|
Mounting flanges
|
38×38mm
|
||
Weight
|
≤380 g
|