Product Main

Specifications

1.      50KW//30KHz: High frequency machine can cover all body parts, undertake general radiography and obtain clear images.
2.      There is no other x-ray machine more cost-effective in the world. Moreover, you will sure be pleasantly surprised by the ultra-low price.
3.      If you have mobile DR flat, that will be fantastic! A slight upgrade can help you realize direct digital imaging.
4.      Its solid & streamline shape, as well as its ultra-long service life, make it well worth the cost.
5.      With microcomputer control program and auto-generation of radiography conditions, it’s easy to operate and has good repeatability.
 
Features
1. High precision control mode through analog & digital double-loop control: Adopting HF (≥30kHz) inverter circuit combined with analog & digital double-loop control mode (composed  of microprocessor and PWM dedicated chip), in order to achieve high-precision high voltage output. Power supply fluctuation may occur, but there is still steady x-rays output.
2. High-precision control in radiography time: Minimum exposure time is 0.0025 second, and quick radiography is accessible at any time without the influence of power phase, thus high-quality images are easily achieved and radiation to patients is minimized.
3. High-precision tube current control: The heating of x-ray tube adopts dual-stage high frequency converter, through taking sample tube current by high-speed running A/D converter and implement real-time control through micro-processor. The micro-processor controls the safe load of x-ray tube, and the best radiographic conditions can be set.   
4. Various parameter-setting keys: You can select kV, mA and mAs to set the desirable radiography conditions. With quick human body parts programming, it simplifies the operation procedures. Capacity protection can be fulfilled by locking the three-parameter option keys, according to the capacity constraint of x-ray tube.
5. Self-protection & self-diagnosis: Once malfunction occurs, generator will self-protection and give an alarm. The malfunction can be detected via error code, and it’s convenient for maintenance.
6. Compact structure, reduce installation space.
 
 
  Product Configuration:
 
No
Part Name
Qty
1
X-ray tube
1
2
Radiographic Table
1
3
collimator
1
4
Microcomputer console
1
5
High-voltage generator,
1
6
High voltage cable
2
7
Vertical bucky stand( Optional)
1
 
 
 
 
Technical parameters of main components
 
CONTENTS
YSX0314
YSX0315
Intermittent mode
100kV ,200mA,20kW
100kV ,500mA,50kW
Power Voltage
380V±10% 50Hz±10%
tube current
Radiography   16mA~200mA
Radiography32mA~630mA
Output Voltage
Radiography 40-125KV  step 1kV;
resistance power
less than  0.5Ω
Output power
20kW
50kw
Exposure Time
Radiography 0.0025s~6.4s adjustable
Radiography  3ms~6s   adjustable
Nominal Frequency
30kHz
Speed of anode rotating
2800r/min
Anode heat capacity
140KHU
150KHU
Focus
Small focus:1.0mm  Big focus:2.0mm
Length*width*height of bed surface
2000mm×750mm×690mmDeviation:±10mm
Horizontal movement distance of table
≥200mm
Vertical movement distance of table
≥900mm
Distance from table surface to film
50mm±2mm
Distance of vertical movement
770mm±10mm;
800mm-1100mm
Moving crosswise (left & right)
+180°~-180°deviation<±2°
Moving lengthways (along ground railway)
≥1300mm
600mm
Fixed beam filtration grid density
≥40 lines/cm.
grid ratio
10:01
Focus Distance
100cm
Cassette size