Product Main

Specifications

Performance

•Universally PC programmable (PCP)

•Galvanic isolation

•2 wire technology, 4 to 20 mA analog output

•High accuracy in total ambient temperature range

•Fault signal on sensor break or short circuit

•Configuration during measurement using configuration kit

•Output simulation

•Customer specific measurement range setting

Application area

• PC programmable (PCP) Temperature head transmitter

for converting various input signals into a standard

4 to 20 mA analogue output signal

• Input:

-Resistance thermometer (RTD)
-Thermocouple (TC)
-Resistance transmitter (Ohm)
-Voltage transmitter (mV)

• Online configuration using a PC with MS181 configuration kit (MS181-PC)

 Input

Type
Type
Measurement ranges
Min.meas.
Ranges
 
Resistance thermometer
(RTD)
 
 
Pt100
Pt500
Pt1000
acc.to IEC 751
-200 to 850 °C (-328to1562 °F)
-200 to 250 °C (-328 to 482 °F)
-200 to 250 °C (-328 to 482 °F)
10 K
10 K
10 K
Ni100
Ni500
Ni1000
acc.toDIN43760
-60 to 180 °C (-76 to 356 °F)
-60 to 150 °C (-76 to 302 °F)
-60 to 150 °C (-76 to 302 °F)
10 K
10 K
10 K

l  Connection type: 2-, 3- or 4-wire connection

l  Software compensation of cable resistance possible in the 2 wire system(0 to 20 Ω)

l  Sensor cable resistance max. 20 Ωper cable

l  Sensor current: ≤0.6 mA
 
Resistance transmitter (Ω)
 
 
       Ω
 
10 to 400 Ω
10 to 2000 Ω
 
   10 Ω
100 Ω
Thermocouple (TC)
B(PtRh30-PtRh6)
C(W5Re-W26Re) 
D(W3Re-W25Re)
    E(NiCr-CuNi)
    J (Fe-CuNi)
    K (NiCr-Ni)
    L (Fe-CuNi)
    N (NiCrSi-NiSi)
    R (PtRh13-Pt)
    S (PtRh10-Pt)
    T (Cu-CuNi)
    U (Cu-CuNi)2
acc.toIEC584 Part 1
0to+1820℃(32to3308°F)
0to+2320°C(32to4208°F)

0to+2495°C(32to4523°F)
-200to+915°C  (-328to1679°F)
-200to+1200°C (-328to2192F) 

-200to+1372°C(-328to2501°F
-200to+900°C(-328to1652F)
-270to+1300°C(-454to2372
F)
0to+1768°C(32to3214°F)
0to+1768°C(32to3214°F)
-200to+400°C(-328to752°F)
-200to+600°C(-328to1112
F)
 
500 K
500 K
500 K
50 K
50 K
50 K
50 K
50 K
500 K
500 K
50 K
50 K
 
l  Cold junction: internal (Pt100) external(0to80°C)
l  Cold junction accuracy: ± 1 K
l  Sensor current: 30nA
Voltage transmitters (mV)
mV
-10 to 100 mV
5 mV
Output(analogue)
 
Output signal
4 to20 mA, 20 to 4 mA
Transmission  behaviour

Temperature linear, resistance linear, voltage linear

Max-load

(V power supply-8V)/0.025A(Current output)

Current limit
≤25 mA
Signal on alarm
•Underranging  linear drop to 3.8 mA
•Overranging   linear rise to 20.5 mA
•Sensor break;sensor short-circuit:
≤3.6mA or ≥21.0mA
Galvanic isolation
1500V AC (input/output)

Primary Technical Characteristics

Measuring range        Set via PC

PC Interface           USB/RS232
 
Convert accuracy       ≤0.1%FS
 
Cold junction accuracy   ±1℃(TC)

Response time          1s

Power supply           8~35V DC
 
Temperature drift        0.01% FS / 1℃
 
Long- term stability     ≤0.1℃ per year or 0.05% per year

Ambient              -40~+85℃