Product Main

Specifications

 

YC1893DAN three phase electric energy meter test system is three phase meter test equipment with neutral current testing function, can measure three phase mechanical meter, electric mechanical meter and electronic meter by the way of automatic, semi-automatic or Manual.  

 

Function:

  • Starting test and creeping test
  • Measuring the different constant meters synchronously. 
  • With the protect function of overload,  short voltage circuit and open current circuit.
  • The testing software with friendly Windows 2000 and XP interface,  include functional module of all kinds of modern energy meter needed,  to reality error test,  harmonic test,  demand test,  influence test.  
  • The stored testing data can be transferred to multi-format for other program using

 

Character:

  • Meter under testing: 3P4W,  3P3W,  1P2W
  • Testing mode: active power,  reactive power,  cross connection reactive power
  • Neutral current test  
  • Installing RS232,  Ethernet communication port in each meter position,  to reality the automatic calibrate of electronic meter 

 

Technical Data:

 

 

YC1893D-6

YC1893D-12

YC1893D-24

YC1893D-48

Number of meter positions

6

12

24

48

Accuracy

0.05

Voltage

Test voltage output (Phase-Neutral)

3×(24V – 288V) (or customized )

Power of the voltage output

3×100VA

3×250VA

3×500VA

3×1000VA

Resolution

Better than 0.01% of full scale value of range

Setting accuracy

Better than 0.05% at the final range value

Stability

Better than 0.005%/h (integration time 150 s)

Load regulation from 0-max. load

Better than 0.01%

Distortion factor

Better than 0.3% for linear resistance load

Harmonics

2nd – 21st free programmable

Current

Test current output

3×(1mA – 100A) 

Power of the current output

3×150VA

3×350VA

3×750VA

3×1500VA

Resolution

Better than 0.01% of full scale value of range

Setting accuracy

Better than 0.05% at the final range value

Stability

Better than 0.005%/h (integration time 150 s)

Load regulation from 0-max. load

Better than 0.01%

Distortion factor

Better than 0.3% for linear resistance load

Harmonics

2nd – 21st free programmable

Phase angle

Range

0 -- 360°

Resolution

0.01°

Setting accuracy

0.1°

Frequency

Range

45Hz – 65Hz

Resolution

0.01Hz

Error display

Type of error display

Red LED

Resolution of the error displays

8 digits

Others

Voltage Supply

3×220/380V±10% or customized

50/60Hz±2Hz

Ambient temperature

-10°C -- +40°C

Relative humidity

35% -- 85%