EVT-6000 Battery Tester Technical Specification
|
||||
|
Project index
|
Parameter index
|
|||
|
Input Power
|
AC 380V ±10% 50Hz/60Hz
|
|||
|
Output range
(customizable)
|
Voltage
|
Current
|
Power
|
|
|
100V~800V
|
±1000A
|
800KW
|
||
|
Resolution
|
14bit
|
|||
|
Control accuracy
|
±0.5% of FS(full scale)
|
|||
|
Measure accuracy
|
±0.5% of FS(full scale)
|
|||
|
Hardware Response Time
|
≤ 1s
|
|||
|
Data Recording Frequency
|
1Hz,10Hz(customizable)
|
|||
|
Support mode
|
Constant Current ,Constant Voltage,
Constant Power,Constant Current and Constant Voltage
|
|||
|
Discharge Power
|
Go back to the grid
|
|||
|
auxiliary channel
(measure the voltage and temperature of cell)
|
Temperature range
|
-25C~110C/
-40C~400C
|
||
|
Temperature accuracy
|
±(1% of reading + 1C)
|
|||
|
Voltage range
|
10mV~5V
|
|||
|
Voltage accuracy
|
± 0.1% of range
|
|||
|
EVT-6000 battery tester application
|
|
|
Project
|
application
|
|
Battery performance testing
|
Power
|
|
Energy
|
|
|
Capacity
|
|
|
Current/voltage
|
|
|
Life cycle testing
|
Over-charge
|
|
Over-discharge
|
|
|
Capacity grading
|
Formation and
capacity grading
|
|
Ratio testing
|
Fast charge testing
|
|
Radio discharge testing
|
|
|
CAN bus
communication interface
|
Support BMU/BMS communication
|