Product Main

Specifications

Power Cord Flexibility Tester

Product details:Model ZLT-JDW1R.This test checks the protection of the supply cord where it enters the appliance. Appliances provided with a supply cord that are moved while in operation shall be constructed so that the supply cord is adequately protected against excessive flexing where it enters the appliance. This does not apply for appliances with automatic cord reels.
The part of the appliance that includes the inlet opening is fixed to the oscillating member so that, when the supply cord is at the middle of its travel, the axis of the cord where it enters the cord guard or inlet is vertical and passes through the axis of oscillation. The major axis of the section of flat cords shall be parallel to the axis of oscillation. 

The cord is loaded so that the force applied is

– 10 N, for cords having a nominal cross-sectional area exceeding 0,75 mm2;

– 5 N, for other cords. 

The distance X, as shown in figure 8, between the axis of oscillation and the point where the cord or cord guard enters the appliance, is adjusted so that when the oscillating member  moves over its full range, the cord and load make the minimum lateral movement. 

The oscillating member is moved through an angle of 90° (45° on either side of the vertical), the number of flexings for  type Z attachments being 20 000 and for other attachments 10 000. The rate of flexing is 60 per minute.

NOTE: A flexing is one movement of 90°.

The cord and its associated parts are turned through an angle of 90° after half the number of flexings, unless a flat cord is fitted. 

During the test, the conductors are supplied at rated voltage and loaded with the  rated current of the appliance.

NOTE: Current is not passed through the earthing conductor. 
Power Supply
220V 50Hz or 115V 60Hz
Test Station
1,adjustable clamp for specimen
Flexing Speed
5-60 times/min(selectable)
Test  Angle
45°, 60°,90° (selectable)
No. of Flex Per Test
1-999999 (selectable)
Load
5N*1,10N*1
Power Output
3KVA, power supply to specimen
Conforms To

IEC60335-1, IEC 60745-1, UL1082, UL1005, UL1647