Product Main

Specifications

 
1. Application
This product is fit for ac rated voltage 450/750V.
2. Working temperature
BV-105 model not more than 105℃, others not more than 75℃, installation temperature not lower than 0℃.
3. Model and name: see table 1
                                                                        Table 1
Model
Name
BV
Copper core PVC insulation power line
BLV
Aluminum core PVC insulation power line
BVR
Copper core PVC insulation flexible power line
BVV
Copper core PVC insulation PVC sheath round power line
BVVB
Copper core PVC insulation PVC sheath parallel power line
BLVVB
Aluminum core PVC insulation PVC sheath parallel power line
BV-105
Copper core heat-resistance 105℃ PVC insulation
4. Technology property
1)Finished insulation core and finished power line are put into the water at the temperature 20±5℃ for an hour. They should be able to experience the AC voltage testing.
2) Outer power line is good at insulation property, mechanics property and non-inflammability with reliable quality and convenient durability.
3) Finished power line should have products name, model and voltage signs.
 
300/500 rubber insulated fixed installed wire (JB 1601-93)
1. Application
This product is suitable for AC rated voltage UO/U 300/500v and below on electrical equipment or lighting installation.
2. Model, name and using place: (see table 1)
                                                                        Table 1
Model
Name
Installation and using place
BXF
BLXF
Copper core rubber insulation chloroprene rubber mixture sheath power line
Al core rubber insulation chloroprene rubber mixture sheath power line
Suitable for indoor and open-air laying and especially in cold area
BXF
BLXF
Copper core rubber insulation chloroprene rubber mixture sheath power line
Al core rubber insulation chloroprene rubber mixture sheath power line
 
BX
BLX
Copper core rubber insulation cotton yarn of other same fiber-weaving power line
Aluminum core rubber insulation cotton yarn of other same fiber-weaving power line
Used for fixed laying either open laying or underground laying
BXR
Copper core rubber insulation cotton yarn of other same fiber-weaving flexible power line
Used for indoor installation
3. Technology property
(1) Insulation core should bear the sparking test or GB/T3048.9 or GB/3048.13. Sparking test made only once.
(2) Sheath
(a) BXF, BLXE model wire should be the same as stipulated to model XH-12A. Generally, it is not inflammable at the temperature If65℃.
(b) The sheath of BXY, BLXY model power line should be of low density or black polythene.
(c) The sheath should be closely tightened on the insulation. The surface of the sheath should be smooth and its color should be well distributed.
(3) The finished product wire should experience soaked voltage testing as stipulated in table3.
                                                                            Table 3
Testing terms
Unit
Property nominal value
The length of sample
M
≥10
Soaking time
H
≥1
Waster temperature
20±5
Testing voltage value
V
2000
Exert voltage time
Min
≥5
PVC insulation flexible wire (GB5023-1997/JB9734-1998)
1. Application
This product is fit for ac rated voltage 450/750V and below of domestic electrical appliances of smaller size electric power tools, of instruments, of various meters and motorized lighting installation.
2. Applying terms
Working temperature: not more than 105℃ for RV-105 model, the other no more than 70℃.
3. Model and names: see table 1
                                                                            Table 1
Model
Name
AVR, RV
Copper core PVC insulation jointed flexible wire
AVRB, RVB
Copper core PVC insulation parallel flexible wire
AVRS, RVS
Copper core PVC insulation twisted jointed flexible wire
RVV
Copper core PVC insulation sheath circle joined flexible wire
RVV
Copper core PVC insulation sheath parallel joined flexible wire
RV-90
Copper core heat-resisted PVC jointed flexible wire
4. Technological property
1) If finished insulation core and finished power line is pot into warm water 20±5℃ for an hour, they will be able to bear stipulated ac sohz, soaked voltage test as stated in table 9.
2) Wire has excellent electric insulation property, mechanical property, non-inflammability. So it is safety and convenience in using the producer’s name, the model and the voltage should be clearly printed on the surface of the finished power link of the insulation and sheath delivery requirements
                                                                              Table 9
Testing name
Testing item
Testing value
Rated voltage of wire
300/500V
450/750V
Finished insulation wire
Testing voltage: in  0.66mm and below
Accordance with
Insulation thickness   Over 0.6mm
1500
2000
 
Voltage testing
Voltage bring to bear on time not less than
5
 
Finished product wire
Voltage testing
Testing voltage
2000
2500
Voltage bring to bear on time not less than
5
5
PVC insulation shielded wire (2JB8734-1998):
1. Application
This product is fit for ac rated voltage300/300V electric appliances, instruments, electro-equipments an automatic installations, the standard for this product is based on the standard made by international electric commission IEC 227(1979) and is exactly the same.
2. Model and name: see table 1
Table 1
Model
Name
AVP
Copper core PVC insulation shielded wire
AVP-105
Heaf-restant 105℃PVC insulation shielded flexible wire
RVP
PVC insulation shielded flexible wire
RVP-90
Heaf-restant 105℃ PVC insulation shielded flexible wire
RVVP
PVC insulation shielded PVC sheath flexible wire
RVVP1
PVC insulation entangled shielded PVC sheath flexible wire
Delivery requirements
1. The length of cables should be in accordance with mutual agreements.
2. Cables delivery should be coiled orderly. Cable tip should be closely wrapped and sealed. Exposed cable tip for AC testing should be long enough to meet the needs. The coiled cable must be in the same model and the same specification.
3. If there is no agreement, the requirements can be in accordance with the contents of following table.
Table 2
Cable name
 
 
 
 
 
PVC insulating wire
100
10
10%
±0.5%
Rubber insulation fixed laying wire at 300/500V rated voltage
100
20
10%
PVC insulating soft wire
100
10
10%
PVC insulating shielded wire
100
10
10%