Earth-water geothermal ground loop heat pumps residential
GHP13-DNNNE, designed and tested by European standard EN14511, approved and tested by TUV china branch. Characterized by its high COP, competitive price and perfect quality.
HISEER GHP13-DNNNE, ground source heat pump, works by using heat stored in the ground from the sun's solar radiation to supply all of the energy required for a home's heating and hot water system.
HISEER geothermal ground source heat pump adopts the following world famous parts:
- Siemens controller
- SWEP or GEA plate type heat exchanger
- Daikin scroll compressor
- Schneider A/C contactor
- Emersion expansion valve
- Emersion dry filter
- Honeywell R410a refrigeration
|
How it works |
|
1.The ground loop |
|
2.A heat pump |
|
3.Heat distribution system |
ADVANTAGES:
- Suitable for the coldest winter area
- The most high efficiency heat pump
- Maintenance free
- Indoor side installation
- No noise level to disturb your neighbor
- Reducing your carbon emission
- Enjoying your green life by installing HISEER heat pumps
- Reducing your heating and cooling bill with high efficiency HISEER heat pumps
GHP13-DNNNE technical
|
Heat pump |
Type |
GHP13-DNNNE |
|
|
Dimensions, weights, connection dimensions |
|||
|
Dimensions |
HxWxD |
960x600X600 |
|
|
Weight |
kg |
145 |
|
|
Refrigerant |
Type |
R410A |
|
|
Filling weight |
kg |
1.8 |
|
|
Permissible operating pressure |
Mpa |
4.2 |
|
|
Pipe connector-hot side |
Inch |
G11/4” |
|
|
Pipe connector-cold side |
Inch |
G11/4” |
|
|
Evaporator |
Type |
Brazed plate heat exchanger |
|
|
Condenser |
Type |
||
|
Compressor |
1xScroll |
||
|
Performance Heat pump |
|||
|
Heat output |
at B0/W35 |
kW |
13.0 |
|
Power consumption |
kW |
2.9 |
|
|
Performance factor |
4.48 |
||
|
Hot side volume flow |
m3/h |
2.24 |
|
|
Cold side volume flow |
m3/h |
2.90 |
|
|
Heat output |
at W10/W35 |
kW |
16.3 |
|
Power consumption |
kW |
2.96 |
|
|
Performance factor |
5.51 |
||
|
Hot side volume flow |
m3/h |
2.80 |
|
|
Cold side volume flow |
m3/h |
3.82 |
|
|
Power |
Type |
Triple phase with Hitachi compressor |
|
|
Sound power level |
dB(A) |
48 |
|
|
The above data is tested by EN14511 |
|
|
|