Earth-water cooled heat pumps for home's heating and hot water system
GHP26/B-DNNNE, designed and tested by European standard EN14511, approved and tested by TUV china branch. Characterized by its high COP, competitive price and perfect quality.
HISEER GHP26/B-DNNNE, ground source heat pump, works by using heat stored in the ground from the sun's solar radiation to supply all of the energy required for a home's heating and hot water system.
HISEER geothermal ground source heat pump adopts the following world famous parts:
- Siemens controller
- SWEP or GEA plate type heat exchanger
- Daikin scroll compressor
- Schneider A/C contactor
- Emersion expansion valve
- Emersion dry filter
- Honeywell R410a refrigeration
How it works |
1.The ground loop |
2.A heat pump |
3.Heat distribution system |
ADVANTAGES:
- Suitable for the coldest winter area
- The most high efficiency heat pump
- Maintenance free
- Indoor side installation
- No noise level to disturb your neighbor
- Reducing your carbon emission
- Enjoying your green life by installing HISEER heat pumps
- Reducing your heating and cooling bill with high efficiency HISEER heat pumps
GHP26/B technical data
Heat pump |
Type |
GHP26/B-DNNNE |
|
Dimensions, weights, connection dimensions |
|||
Dimensions |
HxWxD |
960x600X800 |
|
Weight |
kg |
195 |
|
Refrigerant |
Type |
R410A |
|
Filling weight |
kg |
3.6 |
|
Permissible operating pressure |
Mpa |
4.2 |
|
Pipe connector-hot side |
Inch |
G11/2” |
|
Pipe connector-cold side |
Inch |
G11/2” |
|
Evaporator |
Type |
Brazed plate heat exchanger |
|
Condenser |
Type |
||
Compressor |
2xScroll |
||
Performance Heat pump |
|||
Heat output |
at B0/W35 |
kW |
26.0 |
Power consumption |
kW |
5.80 |
|
Performance factor |
4.48 |
||
Hot side volume flow |
m3/h |
4.47 |
|
Cold side volume flow |
m3/h |
5.79 |
|
Heat output |
at W10/W35 |
kW |
32.6 |
Power consumption |
kW |
5.92 |
|
Performance factor |
5.51 |
||
Hot side volume flow |
m3/h |
5.61 |
|
Cold side volume flow |
m3/h |
7.65 |
|
Cool output |
at W35/W7 |
kW |
27.80 |
Power consumption |
kW |
5.70 |
|
Performance factor |
4.88 |
||
Inside volume flow |
m3/h |
4.78 |
|
Outside volume flow |
m3/h |
5.76 |
|
Power |
Type |
Triple phase with Hitachi compressor |
|
Sound power level |
dB(A) |
49 |
|
The above data is tested by EN14511 |
|