Product Main

Specifications

MODEL
Power Home Inverter 1000VA
Invert
er 500 VA
Inverter 1000 VA
Inverter 2000 VA
CAPACITY
 
500VA/300W
1000VA/600W
2000VA/1200W
AC INPUT
Nominal Voltage
220/230/240VAC
Input Voltage Range
90~280VAC
Nominal Frequency
50/60Hz (Auto Detection)
Input Voltage Range Selector
Narrow
170~280VAC
Wide
90~280VAC
INVERTER MODE
OUTPUT
 
Voltage
230VAC +10/-18%
Frequency
50/60Hz ±0.5Hz
Waveform
Modified Sine-wave
Efficiency (AC to AC)
> 95%
Efficiency (DC to AC)
> 80%
TRANSFER TIME
Transfer Time ( AC to DC )
20ms (Typical)
20ms (Typical)
Transfer Time (DC to AC)
20ms (Typical)
20ms (Typical)
BATTERY
Nominal Voltage
12V DC
24V DC
CHARGER
Charging Voltage
13.7+/-0.2V
27.4+/-0.4V
Charging Current
10A max.
Overcharging Protection
16V+/-0.4V
32V+/-0.8V
TRANSFER
Transfer Time
Typical 15-20ms, 40ms max
INDICATOR
Line Mode
Green LED blinks or lights steadily
Battery Mode
Yellow LED lights
Overload/fault
Red LED blinks or lights steadily
AUDIBLE ALARM
Low Battery Voltage in Battery Mode
Beeps every 2 seconds
Overload
Beeps every 0.5 second.
Fault
Beeps continuously
ENVIRONMENT
Temperature
0 ~ 40°C
 
PHYSICAL
Dimension (mm) DXWXH
255x80x224
Net Weight (Kg)
2.0Kg
2.3Kg
2.5Kg
PROTECTIONS
Deep Discharge, Overcharge, Short Circuit, Overload, Battery Short, Over Voltage, Under Voltage.
           
 
3.Troubleshooting
 
Problem
Possible Causes
Remedy
No LED display
  1. Battery Weak
 
1.  Re-charge battery
  1. Battery defective
2.  Battery replacement.
  1. Power switch is not pressed
3. Press and hold power switch.
Mains normal but works in inverter mode
  1. AC Input  missing
  2. Check AC input connection.
 
2. Input protector is effective
2.  Reset the input protector.
Alarm buzzer beeps continuously
Overload
 
1.  Verify that the load matches the capability specified in the specs.
 
Back up time is shortened
Overload
 
1.  Remove some non-critical load.
Battery voltage is too low.
2.  Charge battery for 8 hours or more.