Technical Data
|
|||
|
|
|||
|
Eversolar string solar inverter TL 5400
|
|||
|
DC input data
|
|
||
|
Max. PV-generator power [W]
|
5400
|
||
|
Max. DC Voltage [V]
|
680
|
||
|
MPPT voltage range [V]
|
125 - 550
|
||
|
Turn off DC Voltage [V]
|
125
|
||
|
Max. DC current [A]
|
25
|
||
|
Nominal DC current [A]
|
22.5
|
||
|
Number of DC connection
|
2
|
||
|
Number of MPP trackers
|
2
|
||
|
DC-connection
|
MC IV-connector
|
||
|
Turn on power [W]
|
10
|
||
|
Output data
|
|
||
|
AC Connector
|
Spring-clamp tech
|
||
|
Power connection
|
Single phase
|
||
|
Rated AC power [W]
|
4600
|
||
|
Max. AC Power [W]
|
5060
|
||
|
Grid voltage range
|
187-264 V
|
||
|
Grid frequency range
|
47.5-50.2 Hz
|
||
|
Rated current [A]
|
20
|
||
|
Max. current [A]
|
25.3
|
||
|
Power factor
|
0.99
|
||
|
Harmonic distortion (THD) at rated output
|
<2%
|
||
|
Power consumption at night [W]
|
<0.2
|
||
|
Power consumption at standby [W]
|
6
|
||
|
Efficiency
|
|
||
|
Max. efficiency
|
97.50%
|
||
|
Euro efficiency (at 360VDC)
|
97.00%
|
||
|
MPPT adaptation efficiency
|
99.50%
|
||
|
Safety equipment
|
|
||
|
Internal overvoltage protection
|
Integrated
|
||
|
DC Insulation monitoring
|
Integrated
|
||
|
Earth fault protection
|
Integrated
|
||
|
Mains monitoring
|
According to VDE 0126-1-1, GB
|
||
|
Earth fault current monitoring
|
According to VDE 0126-1-1, GB
|
||
|
DC current monitoring
|
According to VDE 0126-1-1, GB
|
||
|
Islanding effect monitoring
|
AFI(According to VDE 0126-1-1)
|
||
|
DC disconnector switch
|
Optional DC disconnector with or without load integraed in the device, according to VDE 0100-712
|
||
|
Normative reference
|
|
||
|
CE- compliant according to
|
EN 50178, EN 61000-6-1, EN 61000-6-3, EN 61000-6-2, EN 61000-6-4
|
||
|
EN61000-3-12, EN61000-3-11
|
|||
|
General data
|
|
||
|
Dimensions (WxHxD) [mm]
|
350 x 550 x 170
|
||
|
Weight [kg]
|
25
|
||
|
Housing
|
Aluminium housing for inside and outside installation
|
||
|
Mounting information
|
Wall bracket
|
||
|
Operating temperature range
|
-20°C to +60°C(up 40°C derating)
|
||
|
Relative humidity
|
0% to 98%, no condensation
|
||
|
Site altitude
|
Up to 2000m without derating above sea level
|
||
|
IP protection type
|
IP 65 according to IEC 60529
|
||
|
Isolation type
|
Transformerless
|
||
|
Cooling concept
|
Regulated cooling
|
||
|
Noise level
|
< 40 dBA
|
||
|
LED display
|
3
|
||
|
LCD display
|
Backlight, 16 x 2 Character LCD
|
||
|
Data logger
|
RS485, RS232
|
||
|
Data communication interfaces
|
RS232
|
||
|
Computer Communication
|
|||
|
Standard warranty (option)
|
2 years
|
||