Product Description
Main specification LINUX system Probe element80 elements Channels32 channels digital beaming composite Standard probe: 6.5MHz multi-frequency linear rectal probe VET USE (frequency conversion scope4.0 / 5.0 / 6.5 / 7.5 MHz) Optional probe3.5MHz convex multi-frequency probe (Frequency conversion scope2.0 / 2.5 / 3.5 / 5.0 MHz) Optional probe6.5MHz intra-vaginal frequency conversion probe. (frequency conversion scope4.0 / 5.0 / 6.5 / 7.5 MHz) Optional probe7.5MHz frequency conversion probe. (frequency conversion scope5.0 / 6.5 / 7.5 / 9.0 MHz) Optional probe5.0MHz micro-convex frequency conversion probe. (frequency conversion scope3.5 / 4.5 / 5.0 / 5.5 MHz) Scanning angleconvex probe 60intra-vaginal probe 130 Body markGeneral Bovine, 3.Equine, 4. Canine, 5. Feline, 6.cardio Probe socket 2 sockets, automatically identify the probe Resolutionhorizontal2mmvertical1mm Scanning modeB2B4B B/MM 28 grades depth adjustment under full visual field (10 kinds of magnification) Gain0127dB Dynamic scope27100dBvisible & adjustable Four different angles / switchable width Gray 256 Imaging techniquefull digital beam-composite, continuous dynamic focusing, dynamic aperture Image storage: main unit Disk C 32 MB, 100 frames permanent storage Cine loop256 frames 8 stages TGC control Image processingpre-process (continuous dynamic focus, dynamic aperture, dynamic filter, post-process4 grades gamma correctionframe correlation, black/white reversal, left/right reversal, up/down reversal, edge enhancement, etc. Depth hoist / local zooming Frame frequency30 frames/s Measurement and analysis: Normal measurement: distance, circumference, area(trochoid or el ipse), volume, angle, Stenosis length, area, etc. Obstetric measurement and analysis: EDD and GA of Bovine, Equine, Ovine, Canine, Feline, camel and goat. Cardio measurement and analysis: M routine measurement software package (depth, slope, heart rate, cycle), cardio measurement software package (left ventricle function, mitral valve, aorta, ejection period, cardiac muscle weight, cardio report, etc. Urological measurement and analysis: residual urine, volume of prostate, Urological report Report: OB report, cardio report Notename, age, gender, hospital name, time, date, probe type, frequency, focus, frame correlation, gain, dynamic scope, etc. Language: English Chinese transform Puncture guide, with two approvable guiding lines whose angle and position can be adjustable. USB-A socket for flash disk to store images directly (it can store both patient image and relative report. Support file management, disk management and software update.) USB-B socket for transferring of the real time image (optional software of case report process center) DICOM 3.0 Output: PAL / NTSC Energy-saving 8 kinds internal pseudo color Appointed laser printer can be connected to print the image and report. Standard configuration: Main unit: 1 PC 6.5MHz multi-frequency linear rectal probe 1 PC Probe sockets USB port DICOM 3.0 Optional configuration: 6.5MHz intra-cavity probe (multi frequency) 3.5MHz convex multi-frequency probe 2 PCS 2 PCS 7.5MHz high frequency linear probe (multi frequency) 5.0MHz micro-convex probe (multi frequency) Thermal printer Software of case report process center Normal Laser printer inclung HpLaser jet 1020, 1022, P1007, P1008
Main specification LINUX system Probe element80 elements Channels32 channels digital beaming composite Standard probe: 6.5MHz multi-frequency linear rectal probe VET USE (frequency conversion scope4.0 / 5.0 / 6.5 / 7.5 MHz) Optional probe3.5MHz convex multi-frequency probe (Frequency conversion scope2.0 / 2.5 / 3.5 / 5.0 MHz) Optional probe6.5MHz intra-vaginal frequency conversion probe. (frequency conversion scope4.0 / 5.0 / 6.5 / 7.5 MHz) Optional probe7.5MHz frequency conversion probe. (frequency conversion scope5.0 / 6.5 / 7.5 / 9.0 MHz) Optional probe5.0MHz micro-convex frequency conversion probe. (frequency conversion scope3.5 / 4.5 / 5.0 / 5.5 MHz) Scanning angleconvex probe 60intra-vaginal probe 130 Body markGeneral Bovine, 3.Equine, 4. Canine, 5. Feline, 6.cardio Probe socket 2 sockets, automatically identify the probe Resolutionhorizontal2mmvertical1mm Scanning modeB2B4B B/MM 28 grades depth adjustment under full visual field (10 kinds of magnification) Gain0127dB Dynamic scope27100dBvisible & adjustable Four different angles / switchable width Gray 256 Imaging techniquefull digital beam-composite, continuous dynamic focusing, dynamic aperture Image storage: main unit Disk C 32 MB, 100 frames permanent storage Cine loop256 frames 8 stages TGC control Image processingpre-process (continuous dynamic focus, dynamic aperture, dynamic filter, post-process4 grades gamma correctionframe correlation, black/white reversal, left/right reversal, up/down reversal, edge enhancement, etc. Depth hoist / local zooming Frame frequency30 frames/s Measurement and analysis: Normal measurement: distance, circumference, area(trochoid or el ipse), volume, angle, Stenosis length, area, etc. Obstetric measurement and analysis: EDD and GA of Bovine, Equine, Ovine, Canine, Feline, camel and goat. Cardio measurement and analysis: M routine measurement software package (depth, slope, heart rate, cycle), cardio measurement software package (left ventricle function, mitral valve, aorta, ejection period, cardiac muscle weight, cardio report, etc. Urological measurement and analysis: residual urine, volume of prostate, Urological report Report: OB report, cardio report Notename, age, gender, hospital name, time, date, probe type, frequency, focus, frame correlation, gain, dynamic scope, etc. Language: English Chinese transform Puncture guide, with two approvable guiding lines whose angle and position can be adjustable. USB-A socket for flash disk to store images directly (it can store both patient image and relative report. Support file management, disk management and software update.) USB-B socket for transferring of the real time image (optional software of case report process center) DICOM 3.0 Output: PAL / NTSC Energy-saving 8 kinds internal pseudo color Appointed laser printer can be connected to print the image and report. Standard configuration: Main unit: 1 PC 6.5MHz multi-frequency linear rectal probe 1 PC Probe sockets USB port DICOM 3.0 Optional configuration: 6.5MHz intra-cavity probe (multi frequency) 3.5MHz convex multi-frequency probe 2 PCS 2 PCS 7.5MHz high frequency linear probe (multi frequency) 5.0MHz micro-convex probe (multi frequency) Thermal printer Software of case report process center Normal Laser printer inclung HpLaser jet 1020, 1022, P1007, P1008
Product Feature
Digital technology; 10"SVGA black-and-white displayer; 8 TGC; 0-127dB adjustable Gain; image storage:100 pictures,not lost when interruption of power supply; Cine loop:256 frames; depth hoisting & Wave mirror function fractionated gain function There are 5 kinds of animals and 18 kinds of maternity tables in the maternity package,which can calculate gestational weeks,expected date of confinement and ACFW automatically; Maternity report; 2 probe connectors,which can connect 2 probes simultaneously; Image transmission function; USB Interfaces.
Digital technology; 10"SVGA black-and-white displayer; 8 TGC; 0-127dB adjustable Gain; image storage:100 pictures,not lost when interruption of power supply; Cine loop:256 frames; depth hoisting & Wave mirror function fractionated gain function There are 5 kinds of animals and 18 kinds of maternity tables in the maternity package,which can calculate gestational weeks,expected date of confinement and ACFW automatically; Maternity report; 2 probe connectors,which can connect 2 probes simultaneously; Image transmission function; USB Interfaces.
Product Specification/Models
LINUX system Probe element80 elements Channels32 channels digital beaming composite Standard probe: 6.5MHz multi-frequency linear rectal probe VET USE (frequency conversion scope4.0 / 5.0 / 6.5 / 7.5 MHz) Optional probe3.5MHz convex multi-frequency probe (Frequency conversion scope2.0 / 2.5 / 3.5 / 5.0 MHz) Optional probe6.5MHz intra-vaginal frequency conversion probe. (frequency conversion scope4.0 / 5.0 / 6.5 / 7.5 MHz) Optional probe7.5MHz frequency conversion probe. (frequency conversion scope5.0 / 6.5 / 7.5 / 9.0 MHz) Optional probe5.0MHz micro-convex frequency conversion probe. (frequency conversion scope3.5 / 4.5 / 5.0 / 5.5 MHz) Scanning angleconvex probe 60intra-vaginal probe 130 Body markGeneral Bovine, 3.Equine, 4. Canine, 5. Feline, 6.cardio Probe socket 2 sockets, automatically identify the probe Resolutionhorizontal2mmvertical1mm Scanning modeB2B4B B/MM 28 grades depth adjustment under full visual field (10 kinds of magnification) Gain0127dB Dynamic scope27100dBvisible & adjustable Four different angles / switchable width Gray 256 Imaging techniquefull digital beam-composite, continuous dynamic focusing, dynamic aperture Image storage: main unit Disk C 32 MB, 100 frames permanent storage Cine loop256 frames 8 stages TGC control Image processingpre-process (continuous dynamic focus, dynamic aperture, dynamic filter, post-process4 grades gamma correctionframe correlation, black/white reversal, left/right reversal, up/down reversal, edge enhancement, etc. Depth hoist / local zooming Frame frequency30 frames/s
LINUX system Probe element80 elements Channels32 channels digital beaming composite Standard probe: 6.5MHz multi-frequency linear rectal probe VET USE (frequency conversion scope4.0 / 5.0 / 6.5 / 7.5 MHz) Optional probe3.5MHz convex multi-frequency probe (Frequency conversion scope2.0 / 2.5 / 3.5 / 5.0 MHz) Optional probe6.5MHz intra-vaginal frequency conversion probe. (frequency conversion scope4.0 / 5.0 / 6.5 / 7.5 MHz) Optional probe7.5MHz frequency conversion probe. (frequency conversion scope5.0 / 6.5 / 7.5 / 9.0 MHz) Optional probe5.0MHz micro-convex frequency conversion probe. (frequency conversion scope3.5 / 4.5 / 5.0 / 5.5 MHz) Scanning angleconvex probe 60intra-vaginal probe 130 Body markGeneral Bovine, 3.Equine, 4. Canine, 5. Feline, 6.cardio Probe socket 2 sockets, automatically identify the probe Resolutionhorizontal2mmvertical1mm Scanning modeB2B4B B/MM 28 grades depth adjustment under full visual field (10 kinds of magnification) Gain0127dB Dynamic scope27100dBvisible & adjustable Four different angles / switchable width Gray 256 Imaging techniquefull digital beam-composite, continuous dynamic focusing, dynamic aperture Image storage: main unit Disk C 32 MB, 100 frames permanent storage Cine loop256 frames 8 stages TGC control Image processingpre-process (continuous dynamic focus, dynamic aperture, dynamic filter, post-process4 grades gamma correctionframe correlation, black/white reversal, left/right reversal, up/down reversal, edge enhancement, etc. Depth hoist / local zooming Frame frequency30 frames/s
Application
Intended Application Abdomen, Gynecologic and Obstetric, cardiological, small parts, urological, cardio, etc.
Intended Application Abdomen, Gynecologic and Obstetric, cardiological, small parts, urological, cardio, etc.
Other Information
Measurement and analysis: Normal measurement: distance, circumference, area(trochoid or el ipse), volume, angle, Stenosis length, area, etc. Obstetric measurement and analysis: EDD and GA of Bovine, Equine, Ovine, Canine, Feline, camel and goat. Cardio measurement and analysis: M routine measurement software package (depth, slope, heart rate, cycle), cardio measurement software package (left ventricle function, mitral valve, aorta, ejection period, cardiac muscle weight, cardio report, etc. Urological measurement and analysis: residual urine, volume of prostate, Urological report Report: OB report, cardio report Notename, age, gender, hospital name, time, date, probe type, frequency, focus, frame correlation, gain, dynamic scope, etc. Language: English Chinese transform Puncture guide, with two approvable guiding lines whose angle and position can be adjustable. USB-A socket for flash disk to store images directly (it can store both patient image and relative report. Support file management, disk management and software update.) USB-B socket for transferring of the real time image (optional software of case report process center) DICOM 3.0 Output: PAL / NTSC Energy-saving 8 kinds internal pseudo color Appointed laser printer can be connected to print the image and report.
Measurement and analysis: Normal measurement: distance, circumference, area(trochoid or el ipse), volume, angle, Stenosis length, area, etc. Obstetric measurement and analysis: EDD and GA of Bovine, Equine, Ovine, Canine, Feline, camel and goat. Cardio measurement and analysis: M routine measurement software package (depth, slope, heart rate, cycle), cardio measurement software package (left ventricle function, mitral valve, aorta, ejection period, cardiac muscle weight, cardio report, etc. Urological measurement and analysis: residual urine, volume of prostate, Urological report Report: OB report, cardio report Notename, age, gender, hospital name, time, date, probe type, frequency, focus, frame correlation, gain, dynamic scope, etc. Language: English Chinese transform Puncture guide, with two approvable guiding lines whose angle and position can be adjustable. USB-A socket for flash disk to store images directly (it can store both patient image and relative report. Support file management, disk management and software update.) USB-B socket for transferring of the real time image (optional software of case report process center) DICOM 3.0 Output: PAL / NTSC Energy-saving 8 kinds internal pseudo color Appointed laser printer can be connected to print the image and report.
Origin
China
China