indicator
|
DVL-106C rfid long range reader
|
voltage(V)
|
DC12V(±5%)
|
current(mA)
|
<2A
|
frequency
|
433MHz
|
Infrared frequency
|
38KHz
|
Communication distance(m)
|
tag→reader: 15m at least
|
reader→controller: RS485 output less than 1500m
|
|
reader→controller: Viegand(WG)26, 34 Less than 100m
|
|
degree
|
60 degree
|
Cabling requirements
|
Above 0.3 square millimeter
|
Communication speed
|
19200, n,8,1 (passive RS-485 output)
|
card type
|
AJ06, AJ08, AJ11, AJ10ID, AJ10IC
|
Operating Temperature (℃)
|
-40℃-80℃
|
Operating humidity(%)
|
15%~90%
|
size(mm)
|
L190 × W126× H 25
|
DVL-106C RFID Long Range Active Reader main function
A.Strict 60 ° angle positioning, without interference issues; reading sensitivily, access speed can up to 60 yards, absolute stability within 15 meters.
B.Reader antenna with 3 groups Infrared System (comes with the digital switch by use), with intermittent pulse mode of work, life for 10 years, to avoid the infrared lamp begin to damage within 2 to 3 years.
C.sent immediately afrer reading, you can also set the card number through the computer serial port upload interval, the controller receving the card number too much caused abnormal condition , to avoid parking software show the same card number for a continuous increase in the time of enumeration workload.
D.Super lightning protection features designed to meet any outdoor using condition ; waterproof grade IP66 grade, metal, built-in waterproof boxes,which can avoid water with storm conditions.
E.The body code recognition technology, for the distribution of different body code readers, card readers can work simultaneously to eliminate two adjacent string , the import and export will not interfere with each other.
F.in-build switch adjust the read distance, adjusted within 3 to 15 meters.(any deitail info ,please refer to the user guidance )
G.in-build switch adjust the indoor and out door model, Under indoor conditions regulating infrared signal strength to ensure no reflection problems.
H.can set reading after pressing the loop function in according to the customers requirement.
I.Compatible with all controller,communicate with PC though RS485,WG26 interface.