Product Main

Specifications

Technical Specifications:
Standard:IEC 60252-1:2001
Technical features:
Climate type:40/70/21 or 40/85/21
Capacitance tolerance:± 5%
I.R:≥3000S(MΩ·µF)
Dielectric dissipation factor:tgδ≤0.002 (50Hz~100Hz)
Application requirements:
Altitude:≤2000m
Residual voltage while loading: less than 10% of rated voltage.
Allowed maximum voltage: less than 1.1 times of rated voltage
Permissible maximum current: less than 1.3 times of rated current.
Dimensional specification (mm)
Rated voltage(VAC)
Nominal capacitance(μF)
Size(mm)
D
H
200,250,370,400,440,
450,600,700,1200
3,4,5,7.5,10,12.5,15,17,20,22.5,
25,30,35,40,45,50,55,60,70,80,100,
25+5, 30+5, 35+5, 50+5, 60+5, 70+5, 80+5…
40,45,50,55,
60,63.5,
52*32,71*45
60,65,70,75,80,85,90,
95,100,105,110,115,
120,125,135,138
Note:1.Other capacitance and dimension serials can be specified in compliance with customer's request. 2.Terminal forms can be made in conformity to the requirements of agreements with customers.