Product Main

Specifications

EN 50382 High Temperature Cable

FIREROL FRL-HT-3SU/FRL-HT-6SU
    
                                                                A.Conductor           B.Insulation      
Construction
Conductor
flexible tinned annealed copper wires (red copper only for 150° C core temperature) class 5 according to HD 383
Insulation
silicon rubber according to EN 50382-1 (EI 111)
Electrical & Mechanical Properties
Nominal Voltage 1.8/3 kV or 3.6/6 kV
Maximum Conductor Temperature +120/+150 deg (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 deg (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
  4 x Overall Diameter (D>12mm)
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to mineral oil & fuel oil, acid & alkali
EN 50305 Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO
Fire Performance in general
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804
Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;
NF C 20-902; NF F 16 101; VDE 0472 Teil 816
Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 Low Corrosivity (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Low Toxicity
NFF 16101; NFF 63808; BS6853 Smoke index