Product Main

Specifications

1)Product description:
 
This product is suitable for lightning protection zone:  lightning surge protection of LPZ2 area at the junction with the LPZ3 (D level) power lines.
◆ It has six international standard jack socket and is designed as modular , is easy to install;
◆The material of its shell use imported fire-retardant materials,its set of components  plug bush is phosphor bronze , the products meet international standards and national standards.
◆With advantage of low residual voltage, fast response and long life, built-in overcurrent, overload protection.
◆It  can be inserted 16 kinds of different plugs, full use of every outlet.
 ◆It is mainly applied to the lightning protection (overvoltage) protection of low-voltage single-phase AC power supply (220V AC)system  electrical and electronic equipment.Such as telecommunications equipment, computer and network equipment, medical instruments, precision electronic equipment, household appliances and so on.
 
2)Technology parameters:
 
TYPE: KLF-A5-01
Protection Class: D
Rated voltage Un(V) 220V
Nominal Discharge Current  (8/20μ s) (In): 10KA(8/20μs)
Max. Discharge Current   (8/20μ s) (Imax. ): 20KA(8/20μs)
Voltage Protection Level  Up(KV): ≤1.0KV(20KV   8/20μs)
Max. Continuous Operating Voltage (Uc): 320V
Voltage Protection Level( Up):(V) ≤700V
Response Time:(ns) <20ns
Leakage current(μA): ≤20μA
Maximum load current(A) 10A
Protection Mode: L-PE, N-PE
Interface Model: Five holes trinom
Working Environment: Temperature: -40°C+80°C;Relative humidity: <95%;
Power source jumper length 2.4 meter
Dimension(mm): 335×66×34mm
Weight(kg): 0.672
Order coding: DDC002