Product Main

Specifications

1.       technical performance
●       to subject: liquid, gas or vapour
●       range ability: 
 
LU-CGPS-1200
0-0.25-1.5KPa
LU-CGPS-1300
0-1.2-7.2Kpa
LU-CGPS-1400
0-6-36Kpa
LU-CGPS-1500
0-30-180Kpa
LU-CGPS-1600
0-160-1000Kpa
LU-CGPS-1700
0-400-2500KPa
LU-CGPS-1800
0-1600-10000Kpa
LU-CGPS-1900
0-4000-25000Kpa
LU-CGPS-1000
0-7000-40000Kpa
 
●       output: 4-20mA DC
●       power: 24VDC, it may be 12VDC if non-load, max. is 45VDC
●       load characteristic:
●       positive & negative transfer: up and low may not exceed the range limit after positive & negative transfer, whatever the output is.
Max. positive transfer: 500% of the min. span.
Max. negative transfer: 600% of the min. span.
●       Temperature:
temperature of operating for amplifier: -25℃ ~ +90℃
temperature of operating for sensor:  -40℃ ~ +104℃
●       Relative humidity: 0~100%
●       Sensor capacity changes: <0.16cm3
●       Indicate meter (field): scale gauge length: 30mm,
grade: 2.5
●       Isolating explosion: ds Ⅱ BT5,   Intrinsically-safety: ia Ⅱ CT5
●       Span & Zero: external continually adjusted
●       Over-pressure: 0 (absolute pressure) –14Mpa, when range < 6Mpa;
0 (absolute pressure) –32Mpa, when range < 20Mpa;
0 (absolute pressure) –52Mpa, when range < 42Mpa;
      no damage for transmitter but may cause zero shift, suggest not to operate over-pressure, the max. pressure is 60Mpa for flange template.
●       Damp: continually adjusted when time constant is between 0.2~1.67 seconds.
●       Settling time: 2s,
 
2. performance index (note: test under the condition of none shift, max. range status of sensor, 316L stainless isolating diaphragm and other standard condition)
●       Accuracy: ±0.25% of the span, including the synthesize errors of linear,     change-difference and repeat.
●       Stability: ±0.25% of max. range (12 months)
 
●       Temperature affect:
zero error:±0.5% / 55℃,  zero & range errors:±1.0% / 55℃, when max. range;
zero error:±3.0% / 55℃,  zero & range errors:±3.5% / 55℃, when min. range;
        note: for type LU-CGPS-1200 (1300), temperature affect is double times of above
●        Over-pressure affect: ±0.25% of max. range (according to permitted over-loads for     different ranges)
●       vibration affect: ±0.05% / g of the max. range, when 200Hz, any axis up.
●       Power affect: <0.005%/V of output range
●       Load affect: none affect when voltage >12VDC input to the transmitter.
●       Mounting position affect: may cause zero error max. 0.24Kpa, but can be calibrated,   none affect for range
 
3. structure index:
●       Structure material: diaphragm: 316 stainless steel, hastelloy C, Monel alloy, Tantalum;
                 O ring: Fluorin rubber;
Flange & bolt: 316 stainless steel;
Fill oil: silicon oil;
Electric shell: low-Cu & aluminum alloy
Plating of electric shell: toast lacquer of amido, formyl, ethene & colophony;
●       pressure-lead connector:
flange NPT 1/4 (taper pipe screw thread), (this is the transmitter flange connection);
connection head screw thread NPT 1/2 (taper pipe screw thread), (selected);
integrated needle valve of welded conduit connector (selected)  
●       electric parts connector:
down-lead conduit NPT 1/2 line-through hole;
electric cable connector (selected)
explosion-proof connector (selected)
●       net weight: 2.4kg (exclude the selected parts)