600W/900W Programmable DC Power Supply
|
Introduction |
|
TPW series is a high accuracy programmable DC power supply with single output. MPU control, RS-232/USB interface for PC control, the TPW series facilitates auto test and auto control. The commands of the TPW series are compliant with SCPI commands. Users can easily develop programs to facilitate different applications in auto test and auto control. Digital input fulfilled by rotary dial and keypad input, fast and accurate. Voltage and current regulations by software, avoids human error and makes the TPW series more accurate.
|
|
Features |
|
ü High accuracy, high resolution ü Over load, over voltage, over current, over temperature and reverse polarity protections ü CV and CC operations, auto CV and CC switch ü 122*32 backlit LCD display ü High speed rotary dial and keypad input ü Built-in beeper alarm ü Panel lock and output ON/OFF function ü List mode function, 100 sets save & recall for voltage, current and time setups, easy use in auto test ü Remote sense function ü USB or RS-232 interface, labview driver ü Supports SCPI commands
|
Specifications
|
Model |
TPW-1560 |
TPW-3030 |
TPW-6015 |
TPW-3020 |
TPW-6010 |
|
|
Range |
15V/60A |
30V/30A |
60V/15A |
30V/20A |
60V/10A |
|
|
Rated output (0℃~40℃) |
||||||
|
Voltage |
0~15V |
0~30V |
0~60V |
0~30V |
0~60V |
|
|
Current |
0~60A |
0~30A |
0~15A |
0~20A |
0~10A |
|
|
OVP |
0.1~18V |
0.1~34V |
0.1~64V |
0.1~34V |
0.1~64V |
|
|
OCP |
0.1~62 A |
0.1~34A |
0~17A |
0.1~24A |
0.1~12A |
|
|
Constant Voltage Operation (CV) |
||||||
|
Line regulation |
≤0.01%+4mV |
≤0.01%+3mV |
||||
|
Load regulation |
≤0.1%+5mV |
|||||
|
Recovery time |
≤1.5ms (50% load change) |
|||||
|
Ripple & Noise |
2mVrms, 30mVpp(20Hz~20MHz) |
|||||
|
Temperature co-efficient |
≤300ppm/℃ |
|||||
|
Constant Current Operation (CC) |
||||||
|
Line regulation |
≤0.2%+3mA |
|||||
|
Load regulation |
≤0.2%+5mA |
|||||
|
Ripple & Noise |
≤10mArms |
|||||
|
Display |
||||||
|
Voltmeter |
5 digits display |
|||||
|
Ammeter |
5 digits display |
|||||
|
Setting resolution |
1mV/1mA |
|||||
|
Reading resolution |
1mV/1mA |
|||||
|
Setting accuracy |
Voltage |
±(0.03% of reading + 10mV) (25±5℃) |
||||
|
Current |
±(0.3% of reading + 10mA) (25±5℃) |
|||||
|
Reading accuracy |
Voltage |
±(0.02% of reading +5mV) (25±5℃) |
||||
|
Current |
±(0.05% of reading +10mA) (25±5℃) |
|||||
|
Protection |
Over load, over voltage, over current, over temperature and reverse polarity protections |
|||||
|
Programming interface |
USB or RS-232, support SCPI commands |
|||||
|
Memory |
100 sets |
|||||
|
Insulation |
Between terminals and chassis/other terminals: ≤60VDC |
|||||
|
Power source |
AC220V±10%, 50/60Hz |
|||||
|
Dimension |
230×110×420mm |
230×110×370mm |
||||
|
Weight |
5.5kg |
4.5kg |
||||